Installation, Technical specifications – Lincoln Electric INVERTEC V350-PRO IM679-A User Manual

Page 8

Advertising
background image

V350-PRO

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS -

INVERTEC V350-PRO

INPUT AC VOLTAGE & DC OUTPUT

Product

Ordering

Input AC

Rated DC Output Output

Weight Dimensions

Name Information Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

(continuous)

K1728-1

Factory

Factory

82.5lbs

200

350A / 34V / 60%

(37.4 kg)

14.8” x 13.3” x

Invertec

K1728-2

208-230/

27.8”*

V350- Construction 380-400/

AMPS

Construction (373 x 338 x

PRO

415-460/

5-425

81.5lbs. 706*)mm

60/50 Hz

K1728-4

575

275A / 31V /100%

(36.9 kg)

Advance

1& 3 Phase

* Includes Handles

Process

60/50 Hz

Advance Process

82.5lbs

(37.4 kg)

* Overall Length Including Handle, 27.8” (706mm) without handle.

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

DUTY CYCLE

CURRENT

LENGTH UP 61m (200 FT)

61-76m (200-250 FT)

100%

275

1/0

1/0

60%

350

1/0

2/0

V350-PRO INPUT CURRENT

Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

Recommended

Voltage

Phases

275Amps@

350Amps@

Line Cord

Size Fuse Size Notes

31Volts(100%)

34Volts(60%)

200

1

Not

Not ---

---

Note

1

Recommended Recommended

208

1

70

94

2

125A

Note 2

230

1

62

85

4

125A

Note 2

380

1

Not

Not ---

---

Note

1

Recommended Recommended

400

1

Not

Not

---

---

Note 1

Recommended Recommended

415

1

38

54

6

80A

Note 2

460

1

34

42

8

70A

575

1

27

37

8

50A

200

3

37

50

8

80A

Note 2

208

3

36

50

6

80A

Note 2

230

3

31

42

8

70A

380

3

21

28

8

50A

400

3

20

27

8

50A

415

3

19

26

8

50A

460

3

17

23

8

50A

575

3

14

18

8

35A

Note 1. Not rated is indicated by 4-x's in the box on the rating plate.

AWG