OPERATION

B-7

GENERATOR OPERATION

Be sure that any electrical equipment plugged into
the generator’s AC power receptacles can with-
stand a ±10% voltage and a ±4% frequency varia-
tion. Some electronic devices cannot be powered
by the POWER-ARC 4000. Refer to Table A.2,
ELECTRICAL DEVICE USE WITH THE POWER-
ARC 4000, in the INSTALLATION section of this
manual.

GENERAL INFORMATION

The POWER-ARC 4000 generator is rated at 4000
continuous watts (4400 surge watts). It provides both
120 volt and 240 volt power. You can draw up to 20
amps from either side of the 120 volt duplex recepta-
cle, but no more than 37 amps from both sides at
once. Up to 18 amps can be drawn from the single
240 volt receptacle.

Electrical loads in watts are calculated by multiplying
the voltage rating of the load by the number of amps

it draws. (This information is given on the load device
nameplate.) For example, a device rated 115 volts, 2
amps will need 230 watts of power (115 x 2 = 230).

You can use Table B.3, GENERATOR POWER APPLI-
CATIONS, to determine the wattage requirements of
the most common types of loads you can power with
the POWER-ARC 4000. Be sure to read the notes at
the bottom of the table.

TO USE THE GENERATOR AS AN AUXILIARY
POWER SUPPLY:

1.

Start the gasoline engine. See ENGINE OPERA-
TION
in this section of the manual and the engine
owner’s manual.

2.

Set the current control dial on the output control
panel to “GENERATOR.” See Figure B.1.

3.

Plug the load(s) into the appropriate 120 volt or
240 volt power receptacle.

NOTE: During welding, the maximum generator out-

put for auxiliary loads is 100 watts.

NOTE: You can supply multiple loads as long as the

total load does not exceed 4,000 watts. Be
sure to start the largest loads first.

POWER-ARC 4000

CAUTION