Complete

This means the firing completed as programmed.



Delay DELA is a timer that starts the kiln later. Delay time appears in hours and

minutes.


Temperature

This prompt which appears in Ramp-Hold programming, is asking for

a target temperature. The number is to remind you which segment will use this target temperature.

Electronics

The Sentry circuit board is rated for operation at temperatures up to

158˚F/70˚C. When the circuit gets hotter, the Sentry shuts off. The ELEC option tells you how hot the
circuit board is.

Electronics Too Hot

The Sentry circuit board is too hot, so the kiln was shut off.



Failed The thermocouple failed. This can be due to a broken thermocouple, loose

thermocouple connection on the back of the Sentry, disconnected thermocouple wire, or a defective
controller.

Failed to Heat The kiln cannot heat as fast as you programmed or is not heating at

all.

Firing Too Long The temperature rise is less that 27ْF/15ْC per hour and the firing

time is four hours longer than the current segment was programmed.

Full Speed

The rate, or temperature change per hour, is maximum.


Temperature Hold

When this message appears during Ramp-Hold

programming, it is asking you if you want to hold, or maintain, the target temperature of that segment.
If so, enter the length of hold time in hours and minutes (i.e. 1 hour 20 minutes = 01.20). The number
after Hd is the segment number. Each segment in a Ramp-Hold firing is numbered starting with 1.

Temperature Hold

When this message appears during programming, it is asking

if you want to hold, or maintain, the target temperature. If so, enter the length of hold time in hours
and minutes (i.e. 1 hour 20 minutes = 01.20). When HOLd appears in the program review, it is
showing how much hold time has been entered.

High Temperature Deviation

The temperature is above the temperature deviation

setting in the TEDE option.

Computer ID

The ID option is for connection the Sentry to a personal computer.



Ready to Begin The Sentry must display the idle message before you can begin firing

or programming.


Program Lock With this option activated, a stored program cannot be altered or

removed from memory.

Low Temperature Deviation

This message appears when the kiln is below the

temperature deviation setting in the TEDE option.

CPLT

DELA

˚F 1

ELEC

ETH

FAIL

FTH

FTL

FULL

Hd 1

HOLd

HtdE

ID

IdLE

LOCK

LTdE