TROUBLE SHOOTING

SYMPTOM A: NO AC POWER OUTPUT, THE RED LED LIGHTS.

SYMPTOM B: NO AC POWER OUTPUT, NO LED LIGHTS ARE ON.

6

POSSIBLE CAUSES

SUGGESTION

The connected AC products are rated at more than 150 Watts

(PINV1) , 300 Watts (PINV2) or 400 Watts (PINV3), the

overload shutdown occurred.

Use the product with a total power rating

less than 150 Watts (PINV1) , 300 Watts

(PINV2) and 400 Watts (PINV3) .

The connected AC products are rated at less than 150 Watts

(PINV1) , 300 Watts (PINV2) or 400 Watts (PINV3), the high

starting surge causes the overload shutdown.

Use the product not exceeds the inverter's

surge capacity, 300 Watts (PINV1) , 600

Watts (PINV2) and 800 Watts (PINV3) .

The battery is discharged (alarm sounds)

Recharge battery.

The inverter overheated

Turn off the inverter and allow to cool for 15

minutes. Clear blocked fan (PINV2 / PINV3)

or remove the objects covering the ventilation.

POSSIBLE CAUSES

SUGGESTION

The lighter socket or 12 Volt outlet has been poor contacted

Press plug into socket firmly.

The lighter socket or 12 Volt may require ignition to be on.

Turn key to accessory position.

The fuse of cigarette lighter or 12 Volt outlet is blown

Check vehicle fuses and replace.

The fuse of inverter is blown

Check to make sure the inverter is

connected to a power source with correct

voltage and polarity.

Replace fuse.

The inverter has been connected with reverse DC input

polarity.

The inverter needs repairment

if the probable damage has occurred.

Advertising