SYMPTOM C: THE LOW OUTPUT OF INVERTER IS MEASURED

7

POSSIBLE CAUSES

SUGGESTION

Battery voltage is too low below 10V DC

Recharge battery

The inverter is overload

Reduce load to 150 Watts (PINV1) , 300

Watts (PINV2) and 400 Watts (PINV3)

maximum to maintain regulation.

SYMPTOM D: THE LOW BATTERY IS MEASURED

POSSIBLE CAUSES

SUGGESTION

The poor battery condition

Recharge battery

Inadequate power of excessive voltage drop

Check condition of battery clips and

terminals. Clean or replace as necessary