Notes

If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.8 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.

If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

Operation Details

COOL – Cooling Operation

To set the room temperature at your preference
cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum
mode.

Temperature is not displayed on the remote control
during AUTO operation.

DRY – Soft Dry Operation

Dehumidifies while maintaining the setting
temperature. The Soft Dry Operation is recommended
during the rainy season.

If the room temperature exceeds the setting
temperature, operation switches to Cooling.

The fan speed is rather slow during Soft Dry
Operation.

The humidity may not decrease when the indoor
temperature is lower than the setting temperature on
the remote control.

HEAT – Heating Operation

To warm up the room temperature upon your
preference setting temperature.

Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced. We recommend that you use an additional
heating device when the outdoor ambient air
temperature is low.

FAN – FAN Operation

Circulates air throughout the room.

Purifies and deodorizes the air if the air purifying filter
is used. Fan Operation is recommended during
seasons in which neither Heating nor Cooling is used.

Setting the Fan Speed

• Press 4 to select:-

There are five stages of fan speed in addition to
Auto Fan speed.

AUTO
FAN

Heating
When the temperature of the discharge
air increases, the fan speed increases.
Cooling

Dry

Changes the fan speed to generate a
cool breeze. The air starts to blow out
approximately 40 seconds after the start
of Cooling or Soft Dry.

Setting the Vertical Airflow Direction.

• Press 5 to select:-

Louver adjustment range

The adjustment range is different
for each operation i.e. Heating,
Cooling and Soft Dry. (Fig.at left)

The angle indicated on the remote
control is different from that on the
indoor unit.

The louver angle automatically
changes to prevent condensation
during Cooling and Soft Dry.

When operation stops, the louver
automatically closes.

* Five stages of adjustments can be made in this range.

AUTO

For COOL/DRY operation.
Swing up/down automatically.

For HEAT operation
When the discharge air temperature is
low such as at the start of the heating
operation, the air blows at horizontal
level. As the temperature rises, the hot
air blows in a downwards direction.

AUTO

Notes

Do not adjust the vertical airflow direction louver downward
during Cooling and Soft Dry. Drops of water may condense
on the air outlet vent and drip down.

Use the remote control to change the vertical airflow
direction louver. Using your hands to adjust the direction
may cause the louver to malfunction. If this happens, stop
operation immediately and restart.

Setting the Horizontal Airflow Direction.

• Press 6 to select:-

Use this air conditioner under the following

conditions:

For COOL/DRY operation.
Louvers swing horizontally at a fixed
speed.

For HEAT operation
When air temperature is low, air is sent
in

. When temperature goes up,

louver swing horizontally at a fixed
speed.

AUTO

Heating

Soft

Dry

Cooling,

Fan

About 30°

About 30°

About 60°

AUTO

AUTO

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature-Cooling
(Maximum Temperature-Heating)

Minimum Temperature-Cooling
(Minimum Temperature-Heating)

DBT

32

(30)

16

(2)

WBT

23

(-)

11

(-)

DBT

43

(24)

16

(-5)

WBT

26

(18)

11

(-6)

Indoor

Outdoor

Unit in °C

AUTO

Horizontal
Airflow