Press the socket onto the drive anvil of the Torque Wrench.

Set the Torque Wrench Direction Switch, located on the end of the Torque Wrench,
for clockwise or counterclockwise operation.

Place the socket onto the nut or bolt and pull the Handle steadily until a click is
heard or felt.

Stop pulling the Torque Wrench.

replacing the battery

Except for replacing the battery, all other maintenance functions must be done by
a qualified service technician.

When the Battery has a low charge and needs replacing, the words LOW BATTERY
will appear in the LCD readout. A picture of a Battery will show in the readout when
the Battery has a significant charge existing.

Use a flat head screwdriver or other flat object and place it under the Battery Cover
to lift it out off of the Battery Compartment. Gently remove the Battery Cover-see
Figure 1.

Remove the discharged battery and replace it with a new 3V, CR2032 battery as
marked on the Battery Cover. Install the battery according to the polarity indicated
in the Battery Compartment.

Gently insert the Battery Cover back into place.

inspection, Maintenance, anD cleaning

Warning! Make sure the Power Switch of the tool is in its “OFF” position

before performing any inspection, maintenance, or cleaning procedures.

before each use, inspect general condition of the tool. Check for cracked or

broken parts and any other condition that may affect its safe operation.

Do not use

if damaged. The Wrench is lubricated for life and should not be oiled. The only

exception is the ratchet head which may be lubricated as needed.

Protect the Torque Wrench from rough use. It is a precision instrument and should

be handled and stored with care. Do not throw, use as a hammer, or use as a pry-

ing tool.

Do not iMMerse Wrench or any portion of it in any liquiD. The

plastic grip may be damaged by some industrial solvents. Keep Wrench clean and

dry. Clean with a clean cloth soaked in mineral spirits or denatured alcohol. Store

in a dry location out of reach of children.

This is a precision calibrating instrument. Calibration and servicing must be done
regularly and is the owner’s responsibility.