5.3 Troubleshooting

PLP-601 / PLP-602 / PLP-601R / PLP-602R

Rotor

Display

Content

Checking point

Display lamps are

Battery capacity

Replace with fresh

not turned on.

is low.

batteries or charge

battery

Incorrect battery

Check the polarity

insertion.

of the batteries.

Lamp turns on.

Instrument’s tilt

Turn off the power

exceeds auto leveling

supply and reset the

area. (± 5.7°)

instrument level

Instrument is tilt

(± 5.7°) and turn on

largely by any cause.

again.

After power supply

Turn off the power

turns on, unstable

supply and turn on

state of auto

again.

self-leveling function

Turn off the power

continues

supply and turn on

approx.3 min.

again.

NOTE*

Lamp & lamp

Defect of instrument

Turn off the power

blink mutually

itself.

supply and turn on

again. If the lamps blink

farther, instrument need

to be repaired.

*

NOTE:

When the operation is continued, set the laser beam on the reference

mark and perform it.