Specifications, Detector ls6 – Pentax PLP-602R User Manual

Page 39

Advertising
background image

39

6. Specifications

INSTRUMENT PLP-601R / PLP-602R

Accuracy of reference beam:

± 10” (PLP-601/PLP-601R)
± 12” (PLP-602/PLP-602R)

Measuring range:

Radius 1~200m (PLP-601/PLP-601R)
Radius 1~120m (PLP-602/PLP-602R)

Automatic self-leveling range:

± 10% (± 5.7°)

Light source:

Visible Laser Diode (635nm Max 1.0mW)

Rotation speed:

300rpm / 600rpm (can be switched)

Operation power supply:

4 x D type batteries (PLP-601/ PLP-602)
Rechargeable Ni-MH battery (PLP-601R/ PLP-602R)

Operation time:

24 hours on manganese battery (PLP-601/PLP-602)
48 hours on alkaline battery (PLP-601/PLP-602)
18 hours on Rechargeable Ni-MH battery (PLP-601R/PLP602R)

Charging time:

2 hours (PLP-601R/ PLP-602R)

Waterproof:

IPX6 Watertight type

Working temperature range:

-20°C ~+50°C (-4°F ~ +122°F)

Tripod attaching screw:

JIS/B type (5/8” x 11 thread)

Dimensions:

170w x 170D x 225H mm

Weight:

2.5kg (w/battery)

DETECTOR LS6

Detection Accuracy:

HIGH ± 1mm LOW ± 2.5mm

Beam reception indicator:

Liquid crystal display / buzzer

Sensitivity of vial:

30’ / 2mm

Power supply voltage:

DC9V battery(6F22 or 6LF22)

Operation time:

Approx 40 hours on alkaline battery (6LF22)

Auto power off:

Power supply: Approx.10 min.

Illumination:

Approx.1 min

Dimensions:

140w x 68H x 25L mm / 200g

Advertising
This manual is related to the following products: