Viewing the h.323 activity monitor, Viewing the h.323 activity monitor –55 – Polycom V2IU 4350 User Manual

Page 73

Advertising
background image

Configuring the V2IU 4350

3 - 55

The call could not be established because the system already is at the maxi-
mum allowed bandwidth.

“Received admission reject”

The call was terminated because an admission reject was received from the
gatekeeper.

“Received disengage request”

The call was terminated because the endpoint requested to tear down the call.

“Received invalid data”

The call could not be established because the system received invalid data on
the signaling channel.

“Cannot find client”

The call could not be established because the called client could not be found.

Viewing the H.323 Activity Monitor

To configure the H.323 Activity Monitor, use the following steps:

5.

Using the configuration graphical user interface, from the Configuration

Menu on the left-hand side, click VoIP.

6.

Click H.323 Activity. The window shown below opens.

2.

On this screen, the event list contains three columns:
The Event/Time field - shows the type of event and the time that it

occurred.

The Source field - shows the source of the event as an IP address and

an alias (when available).

The Destination field - shows the destination of the event as an IP

address and an alias (when available).

Advertising