Setting the timer, Convenience operation – Panasonic CS-E9CKP User Manual

Page 3

Advertising
background image

Notes

If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.8 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.

If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

Operation Details

COOL – Cooling Operation

To set the room temperature at your preference
cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum
mode.

Temperature is not displayed on the remote control
during AUTO operation.

DRY – Soft Dry Operation

Dehumidifies while maintaining the setting
temperature. The Soft Dry Operation is recommended
during the rainy season.

If the room temperature exceeds the setting
temperature, operation switches to Cooling.

The fan speed is rather slow during Soft Dry
Operation.

The humidity may not decrease when the indoor
temperature is lower than the setting temperature on
the remote control.

HEAT – Heating Operation

To warm up the room temperature upon your
preference setting temperature.

Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced. We recommend that you use an additional
heating device when the outdoor ambient air
temperature is low.

FAN – FAN Operation

Circulates air throughout the room.

Purifies and deodorizes the air if the air purifying filter
is used. Fan Operation is recommended during
seasons in which neither Heating nor Cooling is used.

Setting the Fan Speed

• Press

4 to select:-

There are five stages of fan speed in addition to
Auto Fan speed.

AUTO
FAN

Heating
When the temperature of the discharge
air increases, the fan speed increases.
Cooling

Dry

Changes the fan speed to generate a
cool breeze. The air starts to blow out
approximately 40 seconds after the start
of Cooling or Soft Dry.

Setting the Vertical Airflow Direction.

• Press

5 to select:-

Louver adjustment range

The adjustment range is different
for each operation i.e. Heating,
Cooling and Soft Dry. (Fig.at left)

The angle indicated on the remote
control is different from that on the
indoor unit.

The louver angle automatically
changes to prevent condensation
during Cooling and Soft Dry.

When operation stops, the louver
automatically closes.

* Five stages of adjustments can be made in this range.

AUTO

For COOL/DRY operation.
Swing up/down automatically.

For HEAT operation
When the discharge air temperature is
low such as at the start of the heating
operation, the air blows at horizontal
level. As the temperature rises, the hot
air blows in a downwards direction.

AUTO

Notes

Do not adjust the vertical airflow direction louver downward
during Cooling and Soft Dry. Drops of water may condense
on the air outlet vent and drip down.

Use the remote control to change the vertical airflow
direction louver. Using your hands to adjust the direction
may cause the louver to malfunction. If this happens, stop
operation immediately and restart.

Setting the Horizontal Airflow Direction.

• Press

6 to select:-

Use this air conditioner under the following

conditions:

For COOL/DRY operation.
Louvers swing horizontally at a fixed
speed.

For HEAT operation
When air temperature is low, air is sent
in

. When temperature goes up,

louver swing horizontally at a fixed
speed.

AUTO

Heating

Soft

Dry

Cooling,

Fan

About 30°

About 30°

About 60°

AUTO

AUTO

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature-Cooling
(Maximum Temperature-Heating)

Minimum Temperature-Cooling
(Minimum Temperature-Heating)

DBT

32

(30)

16

(2)

WBT

23
(-)

11
(-)

DBT

43

(24)

16

(-5)

WBT

26

(18)

11

(-6)

Indoor

Outdoor

Unit in °C

AUTO

Horizontal
Airflow
Direction

Indoor
Unit

Remote
Control

SETTING THE TIMER

Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.

ON-TIMER Operation

To start the air conditioner operation automatically.
• Press

1 to set the operation.

• Press

2 to increase or decrease the time.

• Then press

3.

• To cancel this operation, press

4.

OFF-TIMER Operation

To stop the air conditioner operation automatically.
• Press

5 to set the operation.

• Press

2 to increase or decrease the time.

• Then press

3.

• To cancel this operation, press

4.

Timer Mode Operation Details

• When the ON-Timer is set, operation will start

before the actual set time. This is to allow the room
temperature to reach the setting temperature by the
setting time. (Maximum of 35 minutes in advance).

• Once the timer is set, operation will start and stop

at the same time everyday.

• The current time is not displayed when the timers

are set.

• When both timers are used together, the TIMER

mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.

CONVENIENCE OPERATION

Powerful Mode Operation

To obtain the set temperature quickly.
• Used in winter to warm yourself quickly upon

returning home (Heating + Powerful).

• Used in summer to cool yourself after a hot bath

(Cooling + Powerful).

• Press

6.

* Powerful mode indicator (orange) on the indoor

unit will light up.

• To cancel this operation, press once more.

Note

• The setting temperature and the fan speed changes

automatically in order to heat, cool or dehumidify the
room quickly.

Quiet Mode Operation

To provide quiet operation.
• Press

7.

* Quiet mode indicator on the indoor unit will light

up.

• To cancel this operation, press once more.

Operation Details

• Air flow sound will reduce during operation.

Ionizer Mode Operation

Produce negative ion for fresh air.
• Press

8.

* Ion mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.

Operation Details

• Air conditioner ON:

Provide negative ion during operation.

• Air conditioner OFF:

Provide negative ion with FAN operation.

• If blinking, press

8 twice.

If still blinking, please call service.

CHECK

AUTO

AUTO HEAT

DRY FAN

COOL

FAN

AUTO

RESET CLOCK

MODE

POWERFUL

FAN SPEED

AIR SWING

OFF

CANCEL

ON

SET

1

2

3

TIMER

OFF/ON

3

6

4

1
5

2

QUIET

8

7

Operation

Temperature

Fan Speed

Automatic

HEAT

COOL

DRY

3.5°C higher

2°C lower (For

first 20 minutes)

1°C lower (For

first 20 minutes)

Slightly

Stronger

43

CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5