Rebuilding a failed mirror set, Deleting raid arrays – PNY P-DSA150-PCI-RF User Manual

Page 11

Advertising
background image

Aug/07

MN2036400000

11

Rebuilding a Failed Mirror Set

When a failure to one member occurs, you will be notified either by the

RAID BIOS during boot or by the SATARAID GUI while in

Windows. The steps below will guide you in rebuilding a failed mirror

set.

1.

Replace the failed drive with one of equal or greater capacity, then

start the computer.

2.

During boot press Ctrl+S or F4 to enter the RAID BIOS.

3.

Select Rebuild Mirrored Set then press Enter.

4.

Select the desired set and then press Enter.

5.

Select online rebuild if you wish to rebuild the mirror in the

background when you boot into Windows. Select offline rebuild

if you wish to rebuild the mirror now. This might take some time.

6.

When asked Are You Sure(Y/N)?, press Y to confirm.

7.

The set will be rebuilt.

Deleting RAID Arrays

1.

As the BIOS boots press Ctrl+S or F4 when prompted to enter

the RAID BIOS.

2.

Select Delete RAID Set, then press Enter.

3.

Select the RAID set then press Enter.