Copy ports options, A-12, Copy port options – Paradyne U8777 User Manual

Page 108: Table a-6

Advertising
background image

A. Configuration Options

A-12

May 2002

8700-A2-GB20-40

Copy Ports Options

You can copy the configuration options of one DSX-1 or G.703 interface, or DSL
loop to another using the Copy Ports screen. For Copy Ports options, refer to

Table A-6, Copy Port Options

. To access the Copy Ports screen, follow this menu

selection sequence:

Main Menu

Configuration

Current Configuration

Copy Ports

Table A-6.

Copy Port Options

From: Port

n

Possible Settings: 1, 2, 3, 4, 5, 6, 7, 8
Default Setting: 1

Controls the source of the configuration options.

1 8 – The configuration of the selected port is copied.

To: Port

y

Possible Settings: 1, 2, 3, 4, 5, 6, 7, 8, All
Default Setting: 1

Controls the target of the configuration options.

1 8 – The configuration of the selected port is replaced. If Perform Copy Then
Increment is selected, the port number is incremented by 1 after the copy.

All – The configurations of all ports are replaced by the configuration of the selected
From: Port.

NOTE: Peer IP Address and Circuit Identifier are

not

copied.

main/config/copy

Slot: 18 Model: 87xx

COPY PORTS

From: Port 1

To: Port 2

Perform Copy

Perform Copy Then Increment

--------------------------------------------------------------------------------

ESC for previous menu MainMenu Exit

Save