A. Configuration Options

8700-A2-GB20-40

May 2002

A-13

System Options

For System Options, refer to

Table A-7, System Options

. To access the System

Options screen, follow this menu selection sequence:

Main Menu

Configuration

Current Configuration

System Options

Table A-7.

System Options (1 of 2)

DSL Mode

Possible Settings: LTU, NTU
Default Setting: LTU

Controls whether the unit is configured as a control unit or tributary unit.

LTU – The unit is configured as a control unit (Line Termination Unit).

NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will
request its IP address from the LTU during establishment of the PPP link.

NOTE: Changing this option will reset the card.

Test Timeout

Possible Settings: Enable, Disable
Default Setting: Enable

Allows tests to end automatically. The feature should be enabled when the unit is remotely
managed, so that control can be regained after a test is accidentally executed.

Enable – Loopback and pattern tests end when test duration is reached.

Disable – Tests run until manually terminated from the Network Tests screen or remotely
(network initiated tests). Refer to

Running Network Tests

in Chapter 8,

Testing

.

main/config/system

Slot: 18 Model: 87xx

SYSTEM OPTIONS

DSL Mode: LTU

Test Timeout: Enable

Test Duration (min): 10

Telco Initiated Loopbacks: Enable

(Model 8777)

Remote Telco Line Loopback: Disabled

(Model 8777)

G.703 Line Termination 120 Ohm

(Model 8779)

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit