A. Configuration Options

A-16

May 2002

8700-A2-GB20-40

When a system clock source fails or is misconfigured, an alarm is reported.
Secondary clock failures are not reported unless the primary clock has also failed.
When the primary clock fails, clocking is switched to the secondary clock source, if
available. If a secondary clock is not available, the clock switches to secondary
holdover mode. In holdover mode, the system attempts to generate timing which is
consistent with the last clock reference. A switch is made back to the primary clock
when it becomes available. Holdover mode is meant to be used for short durations
while network synchronization is temporarily disrupted. The switch back to
primary/secondary clock is made when they become available again.

Figure A-1, System Timing

, shows clocking in an LTU.

Figure A-1.

System Timing

Figure A-2, System Clock Configuration Examples

, shows sample system clock

configurations.

Cross-Connect

Framer

DSX-1/

G.703

Driver

Framer

DSL

Transceiver

System

Timing

Module

DSX-1/G.703 Port

Internal Oscillator

System Timing

99-16627