PSB Speakers GLACIER G5C 0018 User Manual

Page 5

Advertising
background image

PSB INDUSTRIES INC.

General Air Division

1202 West 12th Street, Erie, PA. 16501

G5C Dryers

Phone : 814-45—3651 Fax : 814-454-3492

www.PSBINDUSTRIES.com

[email protected]

5/16

Cod. 710.062.01.00 – Rev.08 – 02.05.02


3.5 Dryer Transportation or Long-Term Storage

• Close inlet and outlet valves, switch off the devices (S1) and (ON/OFF), and disconnect power.

• Depressurize the air circuit using the condensate trap TEST button & remove the fill port plug to vent the reservoir.

• Drain the reservoir tank into a suitably sized container by removing right side panel (B) & turning drain valve (A) counter-

clockwise.

• Replace the fill port plug & close the drain valve (A) by turning clockwise.




4.0 MAINTENANCE

4.1 Weekly

• Visually inspect for proper condensate drain operation.


4.2 Monthly

• Isolate the dryer from the compressed air system by closing inlet & outlet valves and release pressure.

• Clean or replace condesate drain trap filter to remove any accumulated debris.


4.3 Semi-annually

• Check compressor electrical current draw against amperage listed on the data plate.

• Remove power from the dryer and clean condenser finned surfaces with compressed air jet.



5.0 EQUIPMENT DATA

Model

G5C-18

G5C-30

G5C-50

G5C-75

G5C-100

G5C-120

G5C-150

G5C-200

G5C-250

G5C-250

Capacity (scfm)*

18 30 60 75

100

120

150 200

250

250

Compressor Power (HP)

1/6 1/4 1/3 1/2 ¾ 1 1-1/2

1-1/2 2 2

Power Supply (V/Ph/Hz)

115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 230/1/60 230/1/60 230/1/60 460/3/60

Rated Current (A)

1.1 3.7 5.2 6.8 8.1 9.2 7.5 7.5 8.5 3

Full Load Current (A)

2 4.6 6.8 8 9.8 11 8.7 10.5

12.5

5.2

Refrigerant Type

R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a

Refrigerant Charge (LBS)

0.66 0.79 1.21 1.21 1.21 1.32 1.75 2.16 2.0 2.0

Connection Size F (NPT)

1/2 1/2 3/4 3/4 ¾ 1-1/2

1-1/2

1-1/2

1-1/2

1-1/2

Weight (lbs)

66 77 119 132 141 203 232 232 247 247

Max. Air Inlet (°F)

113 113 113 113 113 113 113 113 113 113

Max. Ambient (°F)

104 104 104 104 104 104 104 104 104 104

Max. Pressure (psig)

230 230 230 230 230 230 230 230 230 230

*Rated capacity @ air inlet of 100°F & 100 psig, 100°F ambient & 33 – 39° F leaving dewpoint