6.4 Digital Display

Message (NOT flashing)

Description

Numeric Value

Dewpoint Temperature

“ICE”

Energy Saving Standby Mode


6.5 Error Codes

The controller recognizes specific types of operational errors. When an error occurs the display shows a flashing alarm message
alternating with the current dewpoint value, as described below:

Message (flashing)

Cause

HtA

High Dewpoint Temperature

PF1

Temperature Sensor failure


All the alarms except for PF1 are automatically reset when the cause is removed. PF1 must be cleared by switching the unit off and
then re-started. PF1 has a priority over all the other displayed messages.

7.0 TROUBLESHOOTING

SYMPTOM POSSIBLE

ORIGIN

SOLUTION

Temperature shown in
display is higher than
preset value

High compressed air inlet temperature

High compressed air flow

High ambient air temperature

Fouled refrigerant condenser

Low refrigerant charge

Faulty refrigerant compressor

Faulty refrigerant solenoid valve

Faulty fan thermostat

Faulty control relay

Refrigerant high pressure switch open

Reduce air temperature to within design limits

Reduce air flow to within design limits

Increase ventilation rate of installation area

Clean condenser

Locate & repair leak & re-charge

Repair or replace

Repair or replace

Repair or replace

Repair or replace

Eliminate cause & reset switch

Excessive air pressure
drop across dryer

Inlet/outlet piping reversed

Thermostat sensor out of well

Faulty thermostat

Ambient temperature below freezing

Obstruction in air circuit

Connect properly

Re-install

Repair or replace

Install dryer in heated space

Locate & remove blockage

Water present in air
downstream of dryer

Air by-pass valve open

Condensate drain strainer fouled

Faulty condensate drain

High dew point temperature

Close valve

Clean strainer

Repair or replace

See Symptom #1 above