3 replacement instructions, Lower plate, Belt replacement – Panasonic MC-V414 00 User Manual

Page 10: Agitator assembly

Advertising
background image

MC-V414 00

10

3 REPLACEMENT INSTRUCTIONS

3.1.

Lower Plate

3.1.1.

Removal

1. Place handle in low position.
2. Turn the vacuum cleaner over exposing the underside.

Release the lower plate by pressing the two (2) latches
that secure it inward.

3. Separate the lower plate from the vacuum.

3.1.2.

Installation

1. Close the rear belt cover.
2.
3. Hook the front of the lower plate into the slots on the front

of the nozzle housing. Press the lower plate down into
place.

4. Fasten the lower plate by pushing the two (2) latches out-

ward.

5. NOTE: For general servicing, it is necessary to eliminate

pinching of any wire during reassembly. After servicing
any electrical component or enclosure, the unit should be
reassembled and checked for dielectric breakdown or
current leakage.

3.2.

Belt Replacement

3.2.1.

Removal

1. Follow the removal instructions outlined in the AGITATOR

ASSEMBLY REMOVAL/INSTALLATION section.

3.2.2.

Installation

1. Place the new belt around the motor shaft and follow the

installation instructions in the AGITATOR ASSEMBLY
REMOVAL/INSTALLTION section.

3.3.

Agitator Assembly

3.3.1.

Removal

1. The brushes are not replaceable separately. When the

brushes need replacing, the agitator assembly will have
to be replaced.

2. Carefully lift up on the agitator assembly until it clear both

sides of the nozzle housing.

3. Remove the belt from the motor shaft by sliding it off

between the end of the shaft and the nozzle housing.

3.3.2.

Installation

1. Place the belt around the motor shaft.

2. Place the belt around the agitator pulley on the agitator

assembly.

3. Reassemble the new agitator assembly back into the noz-

zle housing by placing the side opposite the belt partially
into the slot. The small tabs should be aligned with the
nozzle. This will hold the agitator in place and leave both
hands free to place enough tension on the belt to allow
that side of the agitator to return to the nozzle housing slot.

4. Rotate the agitator assembly by hand to insure nothing

rubs and to check for correct assembly.

5. Replace lower plate.