Technical data, Dimensions, Connections – Parkinson Cowan Libra User Manual

Page 28: Grill, Hotplate, Oven

Advertising
background image

TECHNICAL DATA

DIMENSIONS

Height

Width

Depth

Overall

1462mm (nominal)

498mm 600mm

(from elbow
to front of door panel)

Height to hotplate

907mm nominal -
see important note 'Location of the Appliance' (see Page 34).

Space for fixing at hotplate level

2mm minimum

600mm

clearance

Nominal

Space for fixing above hotplate level 100mm each side of appliance
Minimum space above grill

500mm

Minimum distance from rear wall

20mm

Weight of appliance

50.0kg

CONNECTIONS

Gas

Rear left hand side of appliance at hotplate level
Rc½ (½" B.S.P. female)

Electric

None

GRILL

Natural Gas

L.P. Gas

Heat Input

3.0kW (10236 Btu/h) 2.75kW (197.5g/h)

Injector Marking

120

80

HOTPLATE

Natural Gas

R.H.F.

R.H.R.

L.H.R.

L.H.F

Heat Input

1.0kW

2.0kW

2.0kW

2.8kW

(3412 Btu/h)

(6824 Btu/h)

(6824 Btu/h)

(9554 Btu/h)

Injector Marking

079

104

104

130

L. P. Gas

R.H.F.

R.H.R.

L.H.R.

L.H.F.

Heat Input

1.0kW

2.0kW

2.0kW

2.7kW

(71.8g/h)

(143.7 g/h)

(143.7 g/h)

(194 g/h)

Injector Marking

51

72

72

83

OVEN

Natural Gas

L P. Gas

Heat Input

2.4kW (8189 Btu/h)

2.4kW (172.4g/h)

Injector Marking

108

78

Thermostat By-pass Marking

69

78

28

Advertising