Eq-500, Specifications – Panasonic EQ-500 Series User Manual

Page 5

Advertising
background image

198

EQ-500

SPECIFICATIONS

Type

0.2 to 2.5 m

0.656 to 8.202 ft

0.1 to 2.5 m

0.328 to 8.202 ft

0.2 to 1.0 m

0.656 to 3.281 ft

0.1 to 1.0 m

0.328 to 3.281 ft

0.2 to 2.5 m

0.656 to 8.202 ft

0.1 to 2.5 m

0.328 to 8.202 ft

0.2 to 1.0 m

0.656 to 3.281 ft

0.1 to 1.0 m

0.328 to 3.281 ft

10 % or less of operation distance

EQ-501

EQ-511

EQ-502

EQ-512

EQ-501T

EQ-511T

EQ-502T

EQ-512T

Multi-voltage

DC-voltage

Adjustable range (Note 1) (Note 2)

Sensing range (at maximum setting distance) (Note 2)

Hysteresis

With timer

With timer

With timer

With timer

Model No.

Item

Supply voltage

Power / Current consumption

Output

Output operation

Short-circuit protection

Response time

Operation indicator

Stability indicator

Distance adjuster

Sensing mode

Timer function

Automatic interference prevention function

Emitting element

Receiving element

Material

Connection method

Cable

Cable length

Weight

Accessory

Protection

Ambient temperature

Ambient humidity

Ambient illuminance

Voltage withstandability

Insulation resistance

Vibration resistance

Shock resistance

Environmental resistance

24 to 240 V AC

ע

10 % or 12 to 240 V DC

ע

10 %

Ripple P-P 10 % or less

12 to 24 V DC

ע

10 % Ripple P-P 10 % or less

AC: 4 VA or less
DC: 3 W or less

AC: 5 VA or less
DC: 4 W or less

AC: 4 VA or less
DC: 3 W or less

AC: 5 VA or less
DC: 4 W or less

45 mA or less

Switchable either Detection-ON or Detection-OFF

Relay contact 1a

• Switching capacity: 250 V AC 3 A (resistive load)

30 V DC 3 A (resistive load)

• Electrical life: 100,000 or more switching operations

(switching frequency 1,200 operations/hour)

• Mechanical life: 50 million or more switching operations

(switching frequency 18,000 operations/hour)

NPN open-collector transistor

• Maximum sink current: 100 mA

• Applied voltage: 30 V DC or less (between output and 0 V)

• Residual voltage: 1 V or less (at 100 mA sink current)

0.4 V or less (at 16 mA sink current)

PNP open-collector transistor

• Maximum source current: 100 mA

• Applied voltage: 30 V DC or less (between output and

ם

V)

• Residual voltage: 1 V or less (at 100 mA source current)

0.4 V or less (at 16 mA source current)

20 ms or less (For EQ-50

T depends on the setting timer period) 2 ms or less (For EQ-51T depends on the setting timer period)

Orange LED (lights up when the output is ON)

Green LED (lights up under stable operating condition)

2-turn mechanical adjuster with indicator

Incorporated (Note 3)

IP67 (IEC)

מ

20 to

55

ЊC

מ

4 to

ם

131

ЊF

(No dew condensation or icing allowed), Storage:

מ

30 to

ם

70

ЊC

מ

22 to

ם

158

ЊF

35 to 85 % RH, Storage: 35 to 85 % RH

Sunlight: 10,000 ?x at the light-receiving face, Incandescent light: 3,000 ?x at the light-receiving face

2,000 V AC for one min. among supply terminals, non-supply metal parts and relay contact output terminals, 1,000 V AC for one min. between relay contacts

100 M , or more, with 500 V DC megger among supply terminals, non-supply metal parts and relay contact output terminals as well as between relay contacts

10 to 55 Hz frequency, 1.5 mm

0.059 in

amplitude in X, Y and Z directions for two hours each

500 m/s

2

acceleration (50 G approx.) in X, Y and Z directions for three times each

Infrared LED (modulated)

2-segment photodiode

Enclosure: ABS, Front cover: Polycarbonate, Display cover: Polycarbonate

Screw-on terminal connection

Suitable for round cable "9 to"11 mm

"

0.354 to "0.433 in

Extension up to total 100 m

328.084 ft

is possible with 0.3 mm

2

, or more, cabtyre cable

Incorporated

Switchable either BGS or FGS function

100 g approx.

85 g approx.

Adjusting screwdriver: 1 pc.

Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer

Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer

Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer

Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer

The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m

0.328 ft

, or more, away.

The adjustable range and the sensing range are specified for white non-glossy paper (200

ן

200 mm

7.874

ן

7.874 in

) as the object.

Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure
to check the operation with the actual sensing object. Refer to ‘Automatic interference function’ (p.8) of ‘PRECAUTIONS FOR PROPER USE’ for
details.

Notes: 1)

2)
3)

08/2005

Advertising