Eq-500, Precautions for proper use – Panasonic EQ-500 Series User Manual

Page 8

Advertising
background image

201

EQ-500

PRECAUTIONS FOR PROPER USE

Part description

Multi-voltage type (L-ON / D-ON mode only)

DC-voltage type

Description

Operation mode switch

Detection-ON mode is obtained when the switch
is turned fully clockwise (L side).

Detection-OFF mode is obtained when the switch
is turned fully counterclockwise (D side).

Operation mode switch

L-ON

D-ON

L-ON

BGS

FGS

D-ON

BGS / FGS function (DC-voltage type only)

DC-voltage type sensor incorporates BGS / FGS function. Select
either the BGS or FGS function depending on the positions of the
background and sensing object.
BGS / FGS function is set with the operation mode switch.
Depends on a selection of either BGS or FGS function, the out-
put operation changes as follows.

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Setting distance

Non-detectable area

Detectable range

Screw for terminal cover fixing

Screwdriver

• The tightening torque for the terminal screws should be 0.3 to 0.5 N⅐m.

Round type

Y-shaped type


The size of conduit is M20

ן

1.5.

If pressure terminals are to be used, affix the connected
pressure terminals to a terminal (M3.5 screw).

Dimensions of the suitable crimp terminals

(Unit: mm

in

)

(After crimping)

7.5

0.295

or less

22

0.866

or less

17

0.669

or less

7

0.276

or less

10

0.394

or less

"

3.6

"

0.142

or more

(After crimping)

7.5

0.295

or less

22

0.866

or less

17

0.669

or less

7

0.276

or less

10

0.394

or less

3.6

0.142

or more



Make sure that the power supply is off while wiring.
Check all wiring before applying power since incorrect wiring may
damage the internal circuit. Also, carefully tighten the terminal
screws so that the wires of adjacent terminals do not touch.
The mounting hole for the terminal cover fixing screws inclines
70 degrees to the terminal cover, as shown in the figure below.
To avoid damaging this product or screw, take care when
tightening or loosening a screw.

To maintain water-resistance, the cable should have an outer
diameter between "9 to "11 mm

"

0.354 to "0.433 in

with a

smooth covering material that allows the attached conduit
connector to be securely tightened; the tightening torque of the
screw should be of 1.5 to 2.0 N

⅐m.

Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power supply
is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this sensor, connect the
frame ground (F.G.) terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause
malfunction due to induction.
If an external surge voltage exceeding 4 kV is impressed (DC-
voltage type: 1 kV), the internal circuit will be damaged, and a
surge suppressing element should be used.
Prepare the cable end as shown below.

Conduit connector construction and cabling

Gland packing (Note)

Gland

Power supply

Conduit connector

Output

37 mm

1.457 in

25 mm

0.984 in

Wiring

When assembling the conduit connector, pay attention to the direction
of the gland packing.
Furthermore, in order to maintain water-resistance, fit the gland
packing such that the seating surface of the gland packing contacts
the packing holder part of the terminal cover evenly.

Note:

Note:

Use crimp terminals with insulating sleeves.
Recommended crimp terminal: Nominal size 1.25

ן

3.5

0.049

ן

0.138

.

Distance adjuster (2-turn)

Adjuster indicator

Stability indicator (Green)

Operation indicator (Orange)

OFF-delay timer adjuster (Note 2)

ON-delay timer adjuster (Note 2)

Operation mode switch (Note 1)

Notes: 1)

2)

The operation mode switch of the DC-voltage type is the DIP
switch. Refer to ‘DC-voltage type’ of ‘Operation mode switch
for details.
Incorporated on EQ-5

T only.

Note: Turn the operation mode switch gradually and lightly with the attached

screwdriver. Turning with excessive strength will cause damage to the
adjuster.

L

D

BGS

FGS

Timer ON

OFF

N.C.

N.C.

L-ON / D-ON mode

BGS / FGS mode

Timer mode

Not used

08/2005