Example

Alarm Input

OTC : +

MSU : 1

DCR : G1

Down the cursor in SETUP

DCR : A1

Move the + sign to right
for Zooming

OST : 00005 : 1

CH #5 will be stilled.

OST : ccccc : m

Every segment in a
multiscreen will be stilled.

Multiscreen Pattern Select

OTC : +

4-segment, 9-segment or 16-segment toggles.

Setup

MSU : n

m = 0 : End Setup
m = 1 : Begin Setup

Cursor Movement and
Parameter Select

DCR : nn

“nn” denotes as follows.

nn = A1

Move the cursor to Right

nn = C1

Move the cursor Upward

nn = E1

Move the cursor to Left

nn = G1

Move the cursor Downward

nn = +1

Select parameter (+)

nn = –1

Select parameter (–)

nn = PD

(Divide into the submenu by SET
button.)

nn = PU

(Return to upper menu by
MENU/ESC button.)

Alarm Recovery

OAL : n

OAL : 0

“n” denotes ALARM indicator status after recov-
ery as follows.

nn = 0 Turns OFF
nn = 1 Turns ON

Still

OST : ccccc : m

“cccc” expresses individual camera channel or
all camera channels in a multiscreen.

ccccc = 00001 to 00128 For individual
ccccc = 00000 For all in a multiscreen

“m” denotes display mode selection.

m = 0: STILL OFF
m = 1: STILL ON

Item

Format

Note/Parameter

Note:

Take a break for at least 270 ms (equivalent to 16 V Sync) from one transmission to the next especially when sending commands con-

secutively.

(Send 1) 5 channel: Alarm mode

[sfx]ADOOA; ALM:[OF][OF][OF]

[OF][B7][OF][efx]

(Response) None
5ch: Alarm mode

b

1

b

2

b

3

a

1

a

2

a

3

a

4

0Fh 0Fh 0Fh 0Fh 87h 0Fh 0Fh

5ch, 15ch, 16ch: Alarm mode

b

1

b

2

b

3

a

1

a

2

a

3

a

4

0Fh 0Fh 0Fh 0Fh 87h 0Fh 3ch

17ch: Alarm mode

b

1

b

2

b

3

a

1

a

2

a

3

a

4

0Fh 0Fh 1Eh 87h 0Fh 0Fh 0Fh

128ch: Alarm mode

b

1

b

2

b

3

a

1

a

2

a

3

a

4

0Fh 0Fh 78h 0Fh 0Fh 0Fh 1Eh

DAI: b

1

b

2

b

3

a

1

a

2

a

3

a

4

b

1

b

2

b

3

=Notice of

First Alarm Channel
a

1

a

2

a

3

a

4

=Notice of

Alarm Channel

b

n

7 6 5 4 3 2 1 0

P P P P O O O O

Checking Code
Data that bit reversed notice
of First Alarm Channel
(3-digit number)

Bit Position

Notice of First Alarm Channel
(3-digit number)
Value: 0 - F

(Example 1) b

n

= 0001 1110

Value: 1

(Example 2) b

n

= 0011 1100

Value: 3

a

n

7 6 5 4 3 2 1 0

P P P P O O O O

Checking Code
Data that bit reversed notice
of First Alarm Channel
(3-digit number)

Bit Position

Notice of First Alarm Channel
(3-digit number)
Value: 0 - F

(Example 1) a

n

= 0001 1110

Value: 1

(Example 2) a

n

= 0011 1100

Value: 3