Connection with the monitors, Connection with the wv-cu360 system controller, Basic connection – Panasonic WJ-FS309 User Manual

Page 26: Loop-through connection, Setting the system controller, Termination for rs-485 chain

Advertising
background image

26

Connection with the WV-CU360
System Controller

Basic Connection

Connect the DATA jack on the Video Multiplexer to
the DATA OUT jack on the System Controller with the sup-
plied RS-485 cable (part of standard accessories of the
System Controller).

Loop-through Connection

1. Plug the branch cable (optional accessory) into the

DATA jack of the Video Multiplexer.

2. Connect one end of the branch cable to the DATA OUT

jack on the System Controller with the supplied RS-485
cable.

DATA

Video Multiplexer

WJ-FS309/FS409/

FS316/FS416

RS-485 Cable

System Controller

WV-CU360

DATA

DATA

System Controller

WV-CU360

DATA

Video Multiplexer

WJ-FS309/FS409/

FS316/FS416

RS-485 Cable

Branch Cable

If the cable is locally procured, make sure it is data
grade cable suitable for RS-485 communication. A 2-
wire twisted pair shielded cable, BELDEN 9406 or
equivalent should be used. Pin assignments and data
flow are shown below.

1

6

1

6

No.

No.

Name

Data Flow

1

1

GND

2

2

RX(B) WJ-FS309/FS316/FS409/FS416

WV-CU360

3

3

RX(A) WJ-FS309/FS316/FS409/FS416

WV-CU360

4

4

TX(B) WJ-FS309/FS316/FS409/FS416

WV-CU360

5

5

TX(A) WJ-FS309/FS316/FS409/FS416

WV-CU360

6

6

GND

Controller
end

Setting the System Controller

The setting is briefly described below. For further details
refer to the Operating Instructions for the WV-CU360
System Controller.

0

9

8

7

6

5

4

3

2

1

CONTROLLER No.

MODE

1

2

3

4

5

6

7

8

OFF

ON

1. Rotate the CONTROLLER NO. switch to set the con-

troller number.

2. Set the 8-bit DIP switch to specify the communication

mode.

Connection with the Monitors

Connect the Monitors to the Spot Output (SPOT OUT)
Connector and Multiscreen (MULTISCREEN OUT) Output
Connector on the rear of the Video Multiplexer.

Video Monitor

Video Monitor

SPOT OUT

MULTI
SCREEN OUT

WJ-FS309/FS409/FS316/FS416

Branch Cable

RS-485 Cable

WV-CU360

Terminator
(If necessary)

Termination for RS-485 chain

Termination is important for stable communications in the
RS-485 chain. It must be located at only one point at the
end positions in the chain.

• If a System Controller is at the end of the chain, set the

5th bit of the DIP switch to ON. See the illustration
above.

• If a Video Multiplexer is at the end of the chain, plug the

terminator (optional accessory) into one end of the
branch cable as shown below.