ALARM/REMOTE Connector

This 25-pin connector connects alarm related control sig-
nals and/or remote switch inputs depending on the status
of pins #5 and #22. The tables below show the pin assign-
ment for the WJ-FS309/FS409 and WJ-FS316/FS416,
respectively.

13

1

25

14

For WJ-FS316/FS416

Pin #

Pin Name

For Alarm

For Remote SW1

For Remote SW2

5

Function 1

Open or +5V

GND

GND

22

Function 2

Open, +5V or 0V

Open or +5V

GND

1

Alarm/Remote 1

Alarm In 1

Remote In 1

Multiscreen

2

Alarm/Remote 2

Alarm In 2

Remote In 2

Still

3

Alarm/Remote 3

Alarm In 3

Remote In 3

Zoom

4

Alarm/Remote 4

Alarm In 4

Remote In 4

VCR/CAM

15

Alarm/Remote 5

Alarm In 5

Remote In 5

MENU

16

Alarm/Remote 6

Alarm In 6

Remote In 6

SPOT

17

Alarm/Remote 7

Alarm In 7

Remote In 7

18

Alarm/Remote 8

Alarm In 8

Remote In 8

19

Alarm/Remote 9

Alarm In 9

Remote In 9/Down

10

Alarm/Remote 10

Alarm In 10

Remote In 10/Up

11

Alarm/Remote 11

Alarm In 11

Remote In 11/Left

12

Alarm/Remote 12

Alarm In 12

Remote In 12/Right

13

Alarm/Remote 13

Alarm In 13

Remote In 13/–

23

Alarm/Remote 14

Alarm In 14

Remote In 14/+

24

Alarm/Remote 15

Alarm In 15

Remote In 15/SET

25

Alarm/Remote 16

Alarm In 16

Remote In 16/ESC

9

Alarm Output

Alarm Output

Alarm Output

Alarm Output

8

Alarm Recovery In

Alarm Recovery In

Alarm Recovery In

Alarm Recovery In

6

Alarm Reset Out

Alarm Reset Out

Alarm Reset Out

Alarm Reset Out

21

Sequence

Sequence

Sequence

7

GND

GND

GND

GND

14

GND

GND

GND

GND

20

GND

GND

GND

GND

For WJ-FS309/FS409

Pin #

Pin Name

For Alarm

For Remote SW1

For Remote SW2

5

Function 1

Open or +5V

GND

GND

22

Function 2

Open, +5V or 0V

Open or +5V

GND

1

Alarm/Remote 1

Alarm In 1

Remote In 1/Down

Multiscreen

2

Alarm/Remote 2

Alarm In 2

Remote In 2/Up

Still

3

Alarm/Remote 3

Alarm In 3

Remote In 3/Left

Zoom

4

Alarm/Remote 4

Alarm In 4

Remote In 4/Right

VCR/CAM

15

Alarm/Remote 5

Alarm In 5

Remote In 5/–

MENU

16

Alarm/Remote 6

Alarm In 6

Remote In 6/+

SPOT

17

Alarm/Remote 7

Alarm In 7

Remote In 7/SET

18

Alarm/Remote 8

Alarm In 8

Remote In 8/ESC

19

Alarm/Remote 9

Alarm In 9

Remote In 9

10

11

12

13

23

24

25

9

Alarm Out

Alarm Out

Alarm Out

Alarm Out

8

Alarm Recovery In

Alarm Recovery In

Alarm Recovery In

Alarm Recovery In

6

Alarm Reset Out

Alarm Reset Out

Alarm Reset Out

Alarm Reset Out

21

Sequence

Sequence

Sequence

7

GND

GND

GND

GND

14

GND

GND

GND

GND

20

GND

GND

GND

GND

–: No Operation