Appendix, Communication protocol, Command table – Panasonic WJ-FS309 User Manual

Page 40: Video multiplexer to system controller, System controller to video multiplexer

Advertising
background image

40

Data format

Format

(Send 1) 5 channel: Alarm mode

[sfx]ADOOA; ALM:[OF][OF][OF]

[OF][B7][OF][efx]

(Response) None
5ch: Alarm mode

b

1

b

2

b

3

a

1

a

2

a

3

a

4

0Fh 0Fh 0Fh 0Fh 87h 0Fh 0Fh

5ch, 15ch, 16ch: Alarm mode

b

1

b

2

b

3

a

1

a

2

a

3

a

4

0Fh 0Fh 0Fh 0Fh 87h 0Fh 3ch

17ch: Alarm mode

b

1

b

2

b

3

a

1

a

2

a

3

a

4

0Fh 0Fh 1Eh 87h 0Fh 0Fh 0Fh

128ch: Alarm mode

b

1

b

2

b

3

a

1

a

2

a

3

a

4

0Fh 0Fh 78h 0Fh 0Fh 0Fh 1Eh

APPENDIX

This appendix details the elements for communication between the Video Multiplexers and the System Controller. For BAUD
RATE, DATA BIT, PARITY CHECK, STOP BIT and WAIT TIME, see page 20 COMMUNICATION SETUP menu.

uuu=001 to 099 (Unit address)

Communication Protocol

Data Format

A message consists of [STX], [Address], [;], [Command],
[;], [Parameter], and [ETX]. [Address] is expressed as
[Aduuu] where uuu is in the range of 001 through 099 in
decimal form to identify the unit number of the Video
Multiplexer.

Notice of alarm occurrence

ALM: b

1

b

2

b

3

a

1

a

2

a

3

a

4

b

1

b

2

b

3

=Notice of

First Alarm Channel
a

1

a

2

a

3

a

4

=Notice of

Alarm Channel

b

n

Item

Format

Example

These notice messages will not be implemented if the ALARM DATA is set to OFF in the SETUP menu of the Video Multiplexer.

Command Table

1. Video Multiplexer to System Controller

Code

[STX] [ADuuu] [;] [Command] [;] [Parameter] [EXT]

ASCII

(02H) ( ) ( ) ( ) ( ) ( ) (03H)

7 6 5 4 3 2 1 0

P P P P O O O O

Checking Code
Data that bit reversed notice
of First Alarm Channel
(3-digit number)

Bit Position

Notice of First Alarm Channel
(3-digit number)
Value: 0 - F

(Example 1) b

n

= 0001 1110

Value: 1

(Example 2) b

n

= 0011 1100

Value: 3

a

n

7 6 5 4 3 2 1 0

P P P P O O O O

Checking Code
Data that bit reversed notice
of First Alarm Channel
(3-digit number)

Bit Position

Notice of First Alarm Channel
(3-digit number)
Value: 0 - F

(Example 1) a

n

= 0001 1110

Value: 1

(Example 2) a

n

= 0011 1100

Value: 3

Single Spot Camera Select

OCS : ccccc

OCS : 00005

“ccccc” expresses a camera number.

ccccc = 00001 to 00128

Sequence activation

OQT : 01F

OQT : 01F

VCR/Camera select

OVC : m

OVC : 1

“m” denotes display mode selection.

m = 0: Camera mode
m = 1: VCR mode

Electronic Zoom

OZM : +

OZM : +

Normal, Normal with + sign, x2 zoomed and
Normal are circulated.

Item

Example

Note/Parameter

2. System Controller to Video Multiplexer

Multi or Spot Select

OMS : mmmm

OMS : 0001

“mmmm” = 0001 Multi

= 0002 Spot