Alarm recording (emergency recording), Principle of alarm recording, Alarm and display methods during alarm recording – Panasonic AG-RT850P User Manual

Page 19: Connecting the alarm input connector

Advertising
background image

19

Alarm Recording (Emergency Recording)

When an emergency occurs at the monitoring site during prolonged monitoring and recording, the alarm function is
automatically triggered, and alarm recording is performed.

Principle of Alarm Recording

Alarm input

Alarm reset input

Time lapse mode

Alarm mode

Time lapse mode

Tape end

Tape start

L18 to 240 hours

6 hours

L18 to 240 hours

• When an alarm signal is supplied by an alarm sensor

(door or intercom switch, etc.) during recording in a
time lapse mode, the recording speed is switched to
the 6-hour mode and the details of the state of emer-
gency are faithfully recorded.

Alarm and Display Methods during
Alarm Recording

ALARM display lamp

REC

ALARM

EJECT

REC REVIEW

REC

REV

FWD

TRACKING /

V-LOCK

RESET

PULL OPEN

COUNTER /

TIME MODE

SEARCH

• When an alarm signal is supplied, the alarm display

lamp functions as follows.

Alarm
lamp

Alarm input

Alarm reset
input

Power switch is
pressed twice.

Off

Flashing

On

“A” display
appears

11-17-01 6H
10:14:30 A

Display
switches to
“6H”.

TV monitor

Connecting the Alarm Input
Connector

CAMERA

IN

OUT

TAPE END OUT

WARNING/
REC OUT

REC IN

COMMON

ALARM RESET IN

ALARM IN

AUDIO

SW OUT

AC IN

Alarm switch

4 V – 14 V

Alarm reset switch

Alarm switch

• Alarm recording starts when the alarm switch is set

on. When the alarm reset switch is set ON after
recording has started, alarm recording is released
and operation is returned to the original time lapse
recording mode.

• Alarm recording can be released by pressing the

STOP button during alarm recording.
However, it cannot be released even by pressing the
STOP button if the MENU/REC LOCK switch is at
REC LOCK or INT is lighted on the display.

• Alarm recording can be automatically reset without

supplying the alarm reset input signal.
The reset time can be set for 0.5, 1, 2, 3, 5 or 10
minutes.

• Another option is alarm recording only while the alarm

input signal is supplied.

• Alarm recording is also possible as far as the end of

the tape.

• When the alarm mode is OFF, alarm recording is not

possible even if the alarm switch is set to ON.