Once set, the Reflector sheet Constant and Prism Constant remains on the
measurement screen as “S 0” or “P 0”.

The factory initial of Reflector sheet Constant and Prism Constant are 0.

Once set, each Constant remains in memory even after the power is turned off.

7.2 Changing the temperature

The temperature setting can be changed only when “Atmospheric Correction” has been
set to “ATM INPUT” in “Initial Setting 1”.

Example: Setting the temperature to +22°C

Press [F4] [CORR] in mode B.
(If the instrument is in mode A,
press [F5] [MODE] to enter mode B.)

Press [F4] [

] to move the cursor to “3.TEMP”

and press the [F5] [SELECT]
to enable the temperature to be changed.

Clear the exiting values by pressing [CLEAR] key.
Input 22 by pressing the numeric keys.

Press the [ENT] key to accept the
temperature to +22°C.

Pressing the [ENT] key returns
the instrument to mode A.

SELECT

CORRECTION

1. PRISM CONST *

0mm

2. SHEET CONST *

0mm

3. TEMP

:

+15°C

4. PRESS

:

1013hPa

5.ppm

* 0

ppm

CLEAR

CORRECTION

1. PRISM CONST *

0mm

2. SHEET CONST *

0mm

3. TEMP

:

+15 °C

4. PRESS

:

1013hPa

5.ppm

* 0

ppm

CLEAR

CORRECTION

1. PRISM CONST : *

0mm

2. SHEET CONST *

0mm

3. TEMP

:

+ 2 2°C

4. PRESS

:

1013hPa

5.ppm

* 0

ppm

SELECT

CORRECTION

1. PRISM CONST *

0mm

2. SHEET CONST *

0mm

3. TEMP

:

+22°C

4. PRESS

:

1013hPa *

H.angle

H.dst.

V.dst.

MEAS TARGET

0 SET DISP MODE

MODE A

15°C

S 0

92° 30’ 20”