Appendix, 1 error messages – Pentax R-315EX(NX) User Manual

Page 70

Advertising
background image

70

13. APPENDIX

13.1 Error messages

Warning Message

Meaning

What to do

Displayed when the instrument is
tilted beyond the vertical com-
pensation range (±3’) in case 1
axis or 2 axis automatic compen-
sation is selected. This message
may be temporarily displayed if
the instrument is turned too fast.

The input data exceeds the allow-
able range.

• This message is displayed if a

long distance which is a far
beyond measurable distance of
R-300X series is measured with
a wrong target mode.
Please select a correct target
then measure. If a wrong target
is selected, a correct distance
cannot be measured.

• The measurement distance is

less than 1.5m in Reflector
sheet mode.

• The measurement distance is

less than 1.5m in Prism mode.

• Under too strong sun light.
• Unstable light value owing to

shimmer or obstacles.

• Reflector sheet, Target and

Prism do not face the instru-

ment.

• Reflector sheet, Target and

Prism are not correctly sighted.

• Measurement range is over in

Reflectorless mode.

• Sufficient signal does not return

by sighting sharp edge etc. at
Reflectorless mode.

• The Date Clock is powered by

the built-in lithium battery.

• The lithium battery needs to be

replaced in five years.

Re-level the instrument.
Repair is needed if the message
is displayed when it is properly
leveled.

Press the [ESC] key and enter the
correct data.

Select the correct target mode.

Select a longer point,
or use a tape measure.

Change the object that has
much better reflectivity, or use a
reflecting sheet, or wait until the
sun activity has weakened.

Have the lithium battery
replaced by the dealer from
whom the instrument was
purchased.

Out of tilt range

Excess data

Mismatched
Target

Target is too
close.

Unsuitable
Condition

Li-batt.voltage is low.