When replacing the main pcb, Service position – Panasonic DMC-TZ1GK User Manual

Page 19

Advertising
background image

19

7.2.

When Replacing the Main PCB

After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in
“TSN system”, together with Maintenance software.

7.3.

Service Position

This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.

Table S1 Extension Cable List

CAUTION-1. (When servicing POWER/TOP PCB)

1. Be sure to discharge the capacitor on POWER/TOP PCB.

Refer to “HOW TO DISCHARGE THE CAPACITOR ON POWER/TOP PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.

2. Be careful of the high voltage circuit on POWER/TOP PCB.
3. DO NOT allow other parts to touch the high voltage circuit on POWER/TOP PCB.

No.

Parts No.

Connection

Form

1

VFK1950

FP6501 (SD/AFE) -CCD UNIT

33PIN 0.3 FFC

2

VFK1575C5125

FP9001 (MAIN) - POWER/TOP FPC

51PIN 0.3 FFC

3

VFK1974

FP9002 (MAIN) - LCD UNIT

4PIN 0.5 FFC

4

RFKZ0378

FP9003 (MAIN) - LCD UNIT

19PIN 0.5 FFC

5

VFK1951

FP9004 (MAIN) - BASE SU

39PIN 0.3 FFC

6

RFKZ0379

PP6501 (SD/AFE) - PS9001 (MAIN)

40PIN B to B

Advertising
This manual is related to the following products: