2.109. Query DOT CLOCK

Hexadecimal 02h 51h 44h 43h

03h

Character Q D C

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 *3 *5 03h

Character *2 *4 *6

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Parameters (*1, *2, *3, *4, *5, *6)

32

31

30

Hexadecimal 2Dh

33h 32h 2Dh

33h 31h 2Dh

33h 30h

Character

3 2 - 3 1 - 3 0

30 31 32

Hexadecimal 30h 33h 30h 30h 33h 31h 30h 33h 32h

Character 0 3 0 0 3 1 0 3 2

Note:

Only when the input is COMPUTER1 or COMPUTER2, and still image is displayed, this command is acceptable.

In other cases, ER401 is returned.

2.110. Query CLOCK PHASE

Hexadecimal 02h 51h 43h 50h

03h

Character Q C P

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 *3 *5 03h

Character *2 *4 *6

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Parameters (*1, *2, *3, *4, *5, *6)

16

15

14

Hexadecimal 2Dh

31h 36h 2Dh

31h 36h 2Dh

31h 36h

Character

1 6 - 1 6 - 1 4

14 15 16

Hexadecimal 30h 31h 34h 30h 31h 35h 30h 31h 36h

Character 0 1 4 0 1 5 0 1 6

Note:

This command is acceptable only when the input is COMPUTER1 or COMPUTER2. In other cases, ER401 is

returned.

2.111. Query ASPECT

Hexadecimal 02h 51h 53h 31h

03h

Character Q S 1

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 03h

Character *2

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Parameters (*1, *2)

F300 series

AUTO

4:3 16:9 S4:3 THROUGH

Hexadecimal 30h 31h 32h 33h

34h

Character 0 1 2 3 4

FW300 series

AUTO

4:3

16:9

H-FIT V-FIT HV-FIT THROUGH

Hexadecimal 30h 31h 32h 33h 34h 35h

36h

Character 0 1 2 3 4 5

6