Query screen format, Query over scan, Query vga60/480p setting – Panasonic RS-232C User Manual

Page 45: Query digital cinema reality

Advertising
background image

45/49

2.141. Query SCREEN FORMAT

Hexadecimal

02h 51h 53h

46h 03h

Character

Q S F

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 03h

Character *2

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

×

Parameters (*1, *2)

16:10

16:9

Hexadecimal 30h 31h

Character 0 1

Note:

This command is acceptable only for PT-FW300 series. In other models, ER401 is returned.

2.142. Query OVER SCAN

Hexadecimal

02h 51h 4Fh

56h 03h

Character

Q O V

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 03h

Character *2

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Parameters (*1, *2)

0%

3%

5%

7%

Hexadecimal

30h 31h 32h 33h

Character

0 1 2 3

2.143. Query VGA60/480p setting

Hexadecimal

02h 51h 56h

35h 03h

Character

Q V 5

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 03h

Character *2

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Parameters (*1, *2)

VGA60

480p

AUTO

Hexadecimal 30h 31h 32h

Character 0 1 2

2.144. Query DIGITAL CINEMA REALITY

Hexadecimal

02h 51h 50h

44h 03h

Character

Q P D

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 03h

Character *2

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Parameters (*1, *2)

OFF

ON

Hexadecimal 30h 31h

Character 0 1

Note:

This command is available only when an interlaced signal is inputted. In other cases, ER401 is returned.

Advertising