Hot swapping cp and hsc cards, Hot swapping line cards, Hot swapping cp – Paradyne Jetstream CPX-1000 User Manual

Page 125: Hot swapping line, Cards, Hot swapping cp and

Advertising
background image

February 2003

5-11

1000-A2-GN22-00

5. Repair Procedures

Hot Swapping
CP and HSC
Cards

HSC cards are paired with CP cards. When you hot swap the CP-A
card, you also need to swap the HSC-A card. After the HSC card is
replaced, pairing with the CP card is automatically restored.

To hot swap CP and HSC cards, refer to JetVision User’s Guide and:

Step 1

Click the CP card icon in the Tree or Shelf view.

To hot swap an active CP or HSC card, go to Step 2.

To hot swap a standby CP or HSC card, go to Step 3.

Step 2

Perform switchover to place the active card in standby.

Step 3

Place the CP card in the Locked state.

Step 4

Select Configuration > Remove Resources. A prompt displays,
confirming you want to remove the card resources.

Step 5

Click Yes. The card is removed from the Tree and Shelf views.

Step 6

Remove the CP card, followed by its corresponding HSC card (see

Removing and Replacing Cards

on page

5-9

).

Step 7

Insert the HSC card, then insert the CP card, and lock them in place
using the card ejectors (see

Removing and Replacing Cards

on

page

5-9

). (Continue with Step 9 if this is a standby CP or HSC

card.)

Step 8

Select File > Refresh CPX. The new cards appear in the Tree and
Shelf views.

Step 9

Place the CP card in the Unlocked state.

Hot Swapping
Line Cards

When you hot swap a line card, you also need to swap its
corresponding transition card.

Line cards include:

ATM OC-3 Module

Octal T1 and 12-port T1 ECAC

EC and ECAC

STS-1 and STS-1 ECAC

Advertising