3. Installing the CPX-1000

Attach
Ethernet
Cables

Connect the MP module to the CP modules via Ethernet. You can
also connect the CPX shelf to an Ethernet LAN for access via
remote system management.

Attach MP Card
to CP Cards

To establish a communication link on a shelf with either a T1 or
STS-1 configuration:

Step 1

Connect the Ethernet ports on the MP module (at the front shelf) to
the Ethernet ports on the CP A and the CP B card respectively,
using the cables provided (Octal T1 card shown).

Connect the CPX
to the LAN

To connect the CPX to an Ethernet LAN:

Step 1

Plug a CAT-5 straight-through cable into the RJ-45 Ethernet port of
the Management Processor (MP) Transition card.

Step 2

Connect the other end of the cable to the LAN hub or router

Attach CP
Redundancy
Cable

To establish redundancy on the CPX with either a T1 (Octal or
12-port) or STS-1 (without ECAC, or STS-1 with ECAC)
configuration, connect the two CP cards (at the front shelf) using
the cable provided.

1

2

3

4

5

6

8

10

7

9

11

12

13

14

15

16

PWR

ERROR

PWR

ERROR

P
M
C

1

RESET

EXT

ETHERNET

P
M
C

2

COM 1

PWR

10/100
ETHERNET

LNK

2

ACT

LNK

1

ACT

Status

Tx

Rx

ATM 155

Status

Tx

Rx

ATM 155

Status

Tx

Rx

ATM 155

Status

Tx

Rx

ATM 155

BFL

RST

CPCI

USB 1

COM 1

10/100 BASE

T

USB 0

CPU

PCI

ABT

PCI MEZZANINE CARD

10/100
ETHERNET

LNK

2

ACT

LNK

1

ACT

CP2

BFL

RST

CPCI

USB 1

COM 1

10/100 BASE

T

USB 0

CPU

PCI

ABT

PCI MEZZANINE CARD

10/100
ETHERNET

LNK

2

ACT

LNK

1

ACT

CP2

12-Port T1

ECAC Modules

12-Port T1

ECAC

Modules

Management

Processor

Module

ATM OC-3

Modules

Call

Processor

Module Sets

HOT

SWAP

4

8

3

7

2

6

1

5

11

12

9

10

S

A

T

T

A

T

C

TDM-12E1/T1

HOT

SWAP

4

8

3

7

2

6

1

5

11

12

9

10

S

A

T

T

A

T

C

TDM-12E1/T1

HOT

SWAP

4

8

3

7

2

6

1

5

11

12

9

10

S

A

T

T

A

T

C

TDM-12E1/T1

HOT

SWAP

4

8

3

7

2

6

1

5

11

12

9

10

S

A

T

T

A

T

C

TDM-12E1/T1

HOT

SWAP

4

8

3

7

2

6

1

5

11

12

9

10

S

A

T

T

A

T

C

TDM-12E1/T1

HOT

SWAP

4

8

3

7

2

6

1

5

11

12

9

10

S

A

T

T

A

T

C

TDM-12E1/T1

HOT

SWAP

4

8

3

7

2

6

1

5

11

12

9

10

S

A

T

T

A

T

C

TDM-12E1/T1

Attach
MP to CP
cables here

Attach CPX
to LAN here

Attach CP Redundancy
cables here

Advertising