Precision Power A1000/2 User Manual

Page 13

Advertising
background image

POWERLOCK

CONNECTORS

Once you have run both the power and ground wires, then connect
the cables to the amplifier. Cut off excess wire, and using wire
strippers, strip the ends of the power and ground cables
approximately 1/4 inch. Locate the

PowerLock

TM

power and ground

connector (supplied). Using a hex wrench, loosen the screws before
attempting to insert the cable wires. Insert the wires into the
appropriate hole, and tighten the screws. The Power/Ground

PowerLock

TM

will accommodate 4 gauge wire for these amplifiers.

Note: The amplifier comes with the connector inserted into the
amplifier with the wire clamping screws in the up position as
shown below. Use a 3mm hex head wrench to secure the wires
to the connector. If the connector needs to be unplugged from
the amplifier, use a 2.5mm hex head wrench to remove the two
retaining screws from the connector (set aside and save the
retaining screws).

Power wires

Connection to
amplifier

3mm hex

wrench

Remove retaining

screw with a 2.5mm hex

wrench

12