Table 5.3:

Pipe Capacity

Capacity of pipe of different diameters and lengths in cubic feet per hour
[cubic meter per hour] with a pressure drop of 0.3 inches of water [75 kPa]
and a specific gravity of 0.60. No allowance for an ordinary number of
fittings is required.

Table 5.1:

Natural Gas

Based on 1000 Btu/Cubic Ft.

Table 5.2:

LP Gas

Based on 2500 Btu/Cubic Ft.

GAS PIPING

Model

Input

(Cubic Ft/Hr)

Input

(Cubic Meter/Hr)

DE-03
DE-04
DE-05
DE-06

70

105
140
165

2.0
3.0
4.0
4.7

Model

Input

(Cubic Ft/Hr)

Input

(Cubic Meter/Hr)

DE-03
DE-04
DE-05
DE-06

28
42
56
66

0.8
1.2
1.6
1.9

Pipe

Length in

Feet

[Meters]

³⁄₄″″

Pipe

1

″″

Pipe

1

¹⁄₄″″

Pipe

1

¹⁄₂″″

Pipe

10 [3.0]
20 [6.1]
30 [9.1]

40 [12.2]
50 [15.2]
60 [18.3]

278 [7.9]
190 [5.4]
152 [4.3]
130 [3.7]
115 [3.3]
105 [3.0]

520 [14.7]

350 [9.9]
285 [8.1]
245 [6.9]
215 [6.1]
195 [5.5]

1050 [29.7]

730 [20.7]
590 [16.7]
500 [14.2]
440 [12.5]
400 [11.3]

1600 [45.3]
1100[ 31.1]

890 [25.2]
760 [21.5]
670 [19.0]
610 [17.3]

Specific Gravity

0.50

0.55

0.60

0.65

0.70

0.75

Correction Factor

1.10

1.04

1.00

0.96

0.93

0.90

Specific Gravity

0.80

0.85

0.90

1.00

1.10

1.20

Correction Factor

0.87

0.84

0.82

0.78

0.74

0.71

Specific Gravity

1.30

1.40

1.50

1.60

1.70

1.80

Correction Factor

0.68

0.66

0.63

0.61

0.59

0.58

Maximum Capacity Correction Factors for
Specific Gravity other than 0.60.