Ftp client setup – Panasonic WV-NS324 User Manual

Page 46

Advertising
background image

-47-

Note:

Input an external alarm signal of more than

100 ms.

3. Alarm Preset

Select the item by pressing the [o] button, and
click the [SET] button.

1POSI:

Camera performs according to Preset posi-

tion 1 when there is input at ALARM IN 1.

2POSI:

Camera performs according to Preset posi-

tion 2 when there is input at ALARM IN 2.

OFF:

No alarm preset used. Set Preset position 1

and 2 in advance when using this function.

The default setting is OFF.

4. E-mail Notice Setup

E-mail Notice:

In ON position, an e-mail is sent

when alarm arises. The default is OFF.

E-mail Server Address:

Input the Mail Server

Address in not more than 128 numbers or
small letters of one byte. When using DNS,
input "host name. Domain name".

Sender E-mail Address:

Input the Sender E-mail

Address. The default is NW_Camera.
It is named "NW_Camera@(IP address of cam-
era)" when input without the @ mark.

• Select ON or OFF for Attach Image.

ON:

Attaches the alarmed picture to the e-

mail.

OFF:

No picture attached. The default setting

is OFF.

• Click the [SET & REBOOT] button.
• Enter up to 4 destination e-mail addresses,

and click the [SET] button.

• Click the [DEL (delete)] button after selecting

an unwanted e-mail address to delete it.

Notes:

• The e-mail address of the sender is one and

the same as that of the administrator.

• Sending mails is not possible in an environ-

ment that requires authentication for SMPTE or
POP3.

5. Recording Setup

The image fields before and after an alarm input
are stored in the memories of the cameras.

• Set the number of image frames for pre

recording (0 - 20) and post recording (1 - 20).

• Set the recording rate (fps: frame per second).

Pre-recording rates:

1/10, 1/5, 1/3, 1/2, 1, 2,

3.3, 5 ..... The default setting is 1.

Post-recording rates:

1/10, 1/5, 1/3, 1/2, 1, 2,

3.3, 5, 10 ..... The default setting is 1.

• Click the [SET & REBOOT] button.

6. Panasonic Protocol Setup

• Select ON or OFF.

ON:

Sends alarm notice mails to the cus-

tomized destinations.

OFF:

Does not send.

• Enter the destination port. The port number

is exclusively assigned to this function, and
any other usage is not allowed.

• Enter a number of retries from 1 to 25.

• Click the [SET] button.
• Enter a maximum of 8 destination IP

addresses, and click the [SET] button.

• Click the [DEL (delete)] button after select-

ing an unwanted destination to cancel it.

Destination IP Address
Input the Panasonic Protocol Destination IP
Address, and click the [SET] button.

7. External Terminal Output Setup

Alarm output is supplied from the Alarm OUT con-
nector when Terminal 1, Terminal 2 or VMD is in
use.

• Select a signal type :

Pulse:

Holds active status during the specified

time width.

Latch:

Holds active status until reset manually.

• Enter the pulse width (necessary number x

100 ms) if you selected Pulse. A number from
1 to 100 is applicable.

• Click the [SET & REBOOT] button.

8. External Alarm Reset

• Click the [Alarm Reset] button to cancel the

activated alarm.

Note:

Wait around 5 seconds or more when exe-

cuting [SET&REBOOT] button.

FTP Client Setup

Image files can be transferred to the FTP server within
the scheduled time zone.

Advertising