7 user options, User options, Options (section 6.7) and area assignment – Paradox Hellas S.A. Digiplex EVO EVO96 User Manual

Page 17: Lcd icon led lcd icon led

Advertising
background image

14 EVO96

Option

[1]: Access Control

Option

[2]: Can Disarm with Access Card

Option

[3]: Extended Unlocked Period

Options [4] and [5]: Arming with Card

[4] ON, [5] OFF:Regular Arm
[4] OFF, [5] ON:Stay Arm
[4] and [5] ON:Force Arm
[4] and [5] OFF:Disable the Arming with Card feature

Option

[6]:Add Tolerance Window to Schedule

Option

[7]:Code Follows Schedule

Option

[8]:Card to Unlock and Code to Disarm

13. Enter the Access Control card’s serial number within the brackets.

14. Press the [

ENTER

] button to save and exit.

6.6.2 Programming User Access Codes with the DGP2-648BL

1. Enter your [

SYSTEM

MASTER

CODE

] or [

ACCESS

CODE

] with Master feature.

2. Press the [

0

] key to enter the User Programming Menu. The area lights of

areas assigned to your User Access Code and the

P

RG

action light will flash.

3. Press the [

ACC

] key. The area lights of the areas assigned to your User Access

Code and the

A

CCESS

action light will illuminate. The

P

RG

action light will

continue to flash.

4. Enter a 3-digit number (002 to 999) you wish to program. The

A

CCESS

action

light will flash for an unused code. If the code is used,

P

RG

action light and the

first number of the code will illuminate. The

A

CCESS

action and area light will turn

off.

5. Enter a User Code. If you do not want to change an existing one, press the [

U

]

key until you reach User Options. Your keypad will emit a Half Beep when it
switches to User Options. Pre-existing options will illuminate.

6. Program the User Options by turning the options “ON” or “OFF”. Once the

options are programmed, press the [

U

]

key to reach the Area Assignment. Your

keypad will emit a Half Beep when it switches to Area Assignment. Pre-existing
assignments will illuminate.

7. Program the Area Assignment. Press the [

V

]

key to return to User Options or

press [

ENTER

] to save and exit. Your keypad will emit a Confirmation Beep to

confirm the code’s acceptance.

6.7 User Options

Options [1] and [2]: Master Feature
When option [1] is OFF, the User cannot program other users into the system.
When option [1] is ON and option [2] is OFF, the user can program and modify user
access codes (P.I.N. only) and User Labels.

When both options [1] and [2] are ON, the user has Full Master rights. The user can
create or modify user access codes, User Options, User Access Control Options, Access
Card Numbers, User Labels and Area Assignments according to their own programming.
For example, if the Full Master User has access to area #1 and option [4] (Bypass) only,
the Full Master user can only assign area #1 and option [4] to other users in the system.

Option [3]: Duress
When option [3] is ON, the Duress feature is enabled. This feature is used when someone
forces a user to arm or disarm an area(s). By entering a user access code (P.I.N.)
reserved for the Duress feature, the system will arm or disarm the area(s), and then send
a silent alarm to the monitoring station.

LCD

ICON

LED

LCD

ICON

LED

Advertising