20 EVO96

8.1.5 Group 7: Zone Fault

A wireless device is no longer communicating with its receiver, or a connection or
CleanMe

TM

trouble is occurring with your smoke detectors.

8.1.6 Group 8: Clock Loss

The time and date have been reset to the default. This is the only trouble that we
recommend that you correct.

Clock Loss [8] to Set will appear on the

LCD screen after you press the [

TRBL

] button or the [

] key. Refer to section 9.3

on page 22 to set the time and date.

8.2 Event Record Display

The Event Record Display will record the user-initiated actions that occurred in your
system as well as any alarms or troubles (i.e. “Access Granted”). You will only be able to
view the events that occurred in the area(s) assigned to your user access code. Only
available on the DGP2-641BL/RB

To view the Event Record:

1. Enter your [

ACCESS

CODE

].

2. Press the [7] button.
3. If you have access to more than one area, select the area(s) you wish to view.
4. Use the [

S] and [T] buttons to scroll between the events.

5. Press the [

CLEAR

] button to exit.

Once you have entered Event Record Display mode, you can change the order that the
Event Record screens appear by pressing the [7] button. If you already know the number
of the event you want to view, press the [

MEM

] button after step 3 above, and then enter

the event's number.