Panasonic WV-CP464 User Manual

Page 10

Advertising
background image

8. Motion Detector Setting (MOTION DET)

The motion detector detects the moving objects in the scene by monitoring changes in
brightness level. You can select the level of sensitivity for motion detection.
When this camera is connected to a compatible intelligent CCTV system, the camera trans-
mits an alarm signal by multiplexing it with the video signal.

1. Move the cursor to the MOTION DET

parameter and select ON.

2. Press

. The MOTION DETECT menu

appears on the monitor screen.

3. Move the cursor to MASK SET and press

. MASK SET lets you set 48 mask areas.

To set MASK SET, proceed as described in steps 2 to 4 of “ALC mode with SUPER-D2
OFF and ELC mode”.

4. Move the cursor to the ALARM parameter and select ON or OFF to set the alarm for

DISPLAY MODE.

Note:

When the system controller WV-RM70, WV-CU550, WV-CU550A, or WV-CU151 is

used with this model, select OFF for ALARM.

5. Move the cursor to DISPLAY MODE and press

to see the current setting. The

masks that detect the brightness changes start blinking.

6. To raise detection sensitivity, press

to return to the MOTION DETECT menu.

7. To obtain the optimum detection level, move the “I” cursor to adjust the level.
8. Repeat the procedures above to obtain a satisfactory setting.

Notes:

• Masking or adjusting the detection level is needed to prevent malfunction under the fol-

lowing conditions:

• When shooting an object under flickering fluorescent light or shooting in ELC.
• When leaves or curtains etc. are swayed by the wind.
• When the object is lighted by lighting equipment that constantly turns on and off.
• It takes about 0.2 seconds for the alarm signal to reach the alarm terminal of the VCR

after the camera detects the object.
Because the alarm signal is multiplexed on the video signal, it may be mistakenly inter-
preted by other video equipment as a time code signal.
Therefore, when the camera is not used in a Panasonic Intelligent CCTV System select
OFF to prevent the above from occurring.

9. Lens Drive Signal Selection (LENS DRIVE)

This item is used to select the type of auto iris lens drive signal to be supplied to the lens
from the auto iris lens connector.

1. Move the cursor to the LENS DRIVE parameter.
2. Select DC if you are using the auto iris lens that requires a DC drive signal.

Select VIDEO if you are using the auto iris lens that requires a video drive signal.

10. Special Menu

This menu lets you adjust and setup the
video signal of the camera to meet your
requirements.
Move the cursor to END on the bottom
line of the CAM SET UP menu and
press and simultaneously
(holding down

and press

) for 2

seconds or more. The SPECIAL menu
appears on the monitor as shown at right.

10-1. Camera Picture Upside Down Positioning (UP SIDE DOWN)

1. Move the cursor to the UP SIDE DOWN parameter.
2. Select ON when you want to turn the picture upside down.

10-2. Chroma Level Setting (CHROMA GAIN)

1. Move the cursor to the CHROMA GAIN parameter.
2. While observing the vectorscope or color video monitor, move the “I” cursor to adjust

the chroma level.

10-3. Aperture Gain Setting (AP GAIN)

1. Move the cursor to the AP GAIN parameter.
2. While observing the wave form monitor or color video monitor, move the “I” cursor to

adjust the aperture gain level.

10-4. Pedestal Level Setting (PEDESTAL)

1. Move the cursor to the PEDESTAL parameter.
2. While observing the wave form monitor or color video monitor, move the “I” cursor to

adjust the pedestal level (black level).

10-5. Chroma Phase (Hue) Setting (HUE)

1. Move the cursor to the HUE parameter.
2. While observing the vectorscope or color video monitor, move the “I” cursor to adjust

the hue (chroma phase) level.

To reset to the factory settings (CAMERA RESET)

1. Move the cursor to the CAMERA RESET parameter. PUSH SW is highlighted.
2. While holding down

and

, press

for 2 seconds or more. The camera is reset

to the factory settings.

** MOTION DETECT **

LEVEL ....I....
- +
DISPLAY MODE

ALARM ON

MASK SET

RET END

** CAM SET UP **
CAMERA ID OFF
ALC/ELC ALC
SHUTTER OFF
AGC ON
SENS UP OFF
SYNC INT
WHITE BAL ATW
MOTION DET OFF
LENS DRIVE DC

END SET UP ENABLE

** SPECIAL **

UP SIDE DOWN OFF
CHROMA GAIN ....I....
AP GAIN ....I....
PEDESTAL .I.......
HUE .I.......
- +

CAMERA RESET PUSH SW

RET END