7.1.1 DIAGNOSIS METHOD

Various protection circuits are provided for this unit. When these
protection circuits are activated, the power of the unit is shut down
(P.D.: Power Down).
The defective parts can be easily diagnosed by observing the LEDs
inside the following assemblies.
1. POWER SUPPLY Assy

For models PRO-610HD/510HD : D915 in the AWV1795
For models SD-582HD5/532HD5 : D915 in the AWV1808

2. DEFLECTION SERVICE Assy

Common to all models

: D321 in the AWV1796

For service assembly

: D321 in the AWV1809

3. CONV. AMP Assy

Common to all models

: D923 in the AWZ6456

How to diagnose a failure

The D915 LED of the POWER SUPPLY Assy always lights up
when the power is turned off because of the protection circuits (P.D.).

P.D.

to P.D (1)

to P.D (2)

to P.D (3)

Is only the LED of the
POWER SUPPLY Assy lit?

Which LED is lit, that of the
DEFLECTION SERVICE Assy
or of the CONV. AMP Assy?

YES

NO

CONV. AMP ASSY

DEFLECTION
SERVICE Assy

D915

POWER SUPPLY ASSY

SIDE A

D321

D923

DEFLECTION SERVICE ASSY

CONV. AMP ASSY

SIDE A

SIDE A