P.d. (1), P.d. (2) – Pioneer PRO-610HD User Manual

Page 28

Advertising
background image

220

PRO-610HD, PRO-510HD, SD-582HD5, SD-532HD5

1. P.D. (1)

Failure in the POWER SUPPLY Assy and the AUDIO Assy.
There are four main possibilities:
1. Abnormality in the regulator of the heater
2. Blown fuse(s) in secondary
3. Abnormality in RELAY (RY102)
4. Abnormality in AUDIO OUTPUT

Status

Causes

Check Items

Probable Defective Parts

D223
ANODE Hi

Abnormality in the regulator for
the heater

The voltage of HT- at TP205 is NOT approx. 19 V, and
that of the HT+ at TP204 is NOT approx. 26 V.

Q201, R202, D210, D209

D207
ANODE Hi

Blown fuse(s)

The voltage HT+ (approx. 26 V) at TP204 is NOT
supplied.

CONV. AMP Assy and
DEFLECTION SERVICE Assy

The voltage (approx. 35 V) at TP203 is NOT supplied.

AUDIO Assy

The voltage (approx. 11 V) at TP209 is NOT supplied.

VIDEO Assy

D911
ANODE Hi

Abnormality in RELAY

The RELAY signal is NOT high (ON) at TP904.

SIGNAL Assy

P.D. even if the RELAY signal is high (ON) at TP904.

Q904, Q905 RY102, R102

D203
ANODE Hi

Abnormality in AUDIO OUTPUT

The SP line (CN5611) is disconnected.

Connect the SP line.

The voltage at the negative electrode of the C5616 and
C5617 is 5.2 V or more.

C5616, C5617 (VIDEO Assy)

Note: The anode of the diode is high only for a short time after the power is turned on until the protection circuits are activated (P.D.) The

LEDs are lit by the HOLD circuit.

In a case when the power cannot be on with no LED lit, check the following:
1. Check if the FU101 fuse in the POWER SUPPLY Assy is blown.
2. Disconnect and check connector E1 (CN201) to see whether STB 5 V is supplied.
If STB 5 V is supplied, replace the SIGNAL Assy. If STB 5 V is NOT supplied, replace the POWER SUPPLY Assy.
3. Disconnect and check connector E1 (CN201) to see whether AC CLK is supplied.
If AC CLK is supplied, replace the SIGNAL Assy. If AC CLK is NOT supplied, replace the POWER SUPPLY Assy.

2. P.D. (2)

Failure in the DEFLECTION SERVICE Assy.
There are four main possibilities:
1. H. deflection overload detection (1)
2. H. deflection stopping detection
3. H. deflection overload detection (2)
4. X-ray protection

Status

Causes

Check Items

Probable Defective Parts

D312
ANODE Hi

Overload detection 1

Q309, Q324 (short-circuited between
C and E)

D309
ANODE Hi

Stopping H. deflection

Is the connector of the deflection yoke plugged in?

Plug in the connector.

No H. OSC signal at TP304 (F=31.5 kHz, Duty 50%)

IC301, Q309

No DH. BLK signal at TP305

Q309

D615
ANODE Hi

Overload detection 2

Q612, Q613 (short-circuited between
C and E)

About one minute after the power is turned off, disconnect
the K4 connector and turn on the power. Then the power is
not turned off (no P.D.).

IC5101, IC5151 and IC5201 in the
CRT DRIVE Assy

D621
ANODE Hi

X-ray protection

No change in the ABL voltage (no DC change) at Pin 12 of
the CN305 when a 100%-white signal is repeatedly
connected and disconnected

D2224 (short-circuited)of the SUB
VIDEO Assy

T601 (FBT) rare short