Troubleshooting – Planet Technology FNSW-2400S User Manual

Page 27

Advertising
background image

FNSW-16/2400S User’s Guide

27

6. TROUBLESHOOTING

S

YMPTOM

Link LED does not lit after cable is connected to
the port.

C

HECKPOINT

4 Verify that the other end of the cable is

connected to a device that is powered on and
on-line.

4 For UTP cable connection to another hub,

verify that only one end of the cable is
connected to a “MDI-II” Uplink port.

S

YMPTOM

100Base-TX port Link LED is lit, Collision LED is
blinking, but traffic is irregular.

C

HECKPOINT

4 Check that the attached device is not set to

dedicated full-duplex. (Some devices use
a physical or software switch to change
duplex modes. Auto-negotiation may not
recognize this type of full-duplex setting.

S

YMPTOM

After setting the DIP-switch of the 100Base-FX
module, the attached device doesn’t
communicate normally with the port.

C

HECKPOINT

4 The attached network device MUST be set

to operate in the same duplex mode.

ALWAYS CHECK THAT THE CABLE, LINK DISTANCES,
AND OVERALL NETWORK DIAMETER ARE WITHIN
SPEC. FOR THE NETWORK TYPE.