A16759

Unit cycles automatically when power is on. When doing
Maintenance, you may be exposed to voltage sources,

compressed air or moving parts. Personal injuries can occur. Before
performing any Maintenance or repair, unplug the compressor and bleed
off all air pressure.

SERVICE AND ADJUSTMENTS

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE TECHNICIAN.

Before servicing:

Unplug or disconnect electrical supply to the air compressor.

Bleed tank of pressure.

Allow the air compressor to cool.

To Replace or Clean Check Valve

1. Release all air pressure from air tank. See "To Drain Tank" in the

Maintenance section.

2. Unplug

outfit.

NOTE: If needed the top panel may be removed to make parts accessible.
3. Using an adjustable wrench loosen

outlet tube nut at air tank and pump.
Carefully move outlet tube away from
check valve.

4. Using an adjustable wrench loosen

pressure relief tube nut at air tank
and pressure switch. Carefully move
pressure relief tube away from check
valve.

5. Unscrew the check valve (turn

counterclockwise) using a 7/8" open
end wrench. Note the orientation for
reassembly.

6. Unscrew elbow fitting from the check valve (turn counterclockwise)

using an adjustable wrench. Note the orientation of the elbow fitting for
reassembly.

7. Using a screwdriver, carefully

push the valve disc up and
down. NOTE: The valve disc
should move freely up and
down on a spring which holds
the valve disc in the closed
position. If not, the check
valve needs to be cleaned or
replaced.

8. Clean or replace the check valve. A solvent, such as paint or varnish

remover can be used to clean the check valve.

9. Apply sealant to the check valve threads. Reinstall the check valve and

elbow fitting (turn clockwise).

10. Replace the pressure release tube. Tighten nut.
11. Replace the outlet tube and tighten nut.
12. Perform the Break-in Procedure. See "Break-in Procedure" in the

Operation section.

Pressure Relief Tube

Check
Valve

Nuts

Outlet Tube

Elbow Fitting

In closed position
disc is visible.

In open position
nothing is visible.