Troubleshooting – Porter-Cable A16759 User Manual

Page 22

Advertising
background image

22- ENG

A16759

TROUBLESHOOTING

Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or

compressed air sources. Personal injury may occur. Prior to attempting
any repairs, unplug the air compressor and bleed off all air tank air
pressure.

PROBLEM

CAUSE

CORRECTION

Pressure switch does
not shut off motor when
compressor reaches "cut-
out" pressure.

Pressure switch "cut-out"
too high.

Move On/Auto/Off lever to
the "OFF" position, if the
outfit does
not shut off contact a Trained
Service Technician.
Contact a Trained Service
Technician.

Excessive
tank pressure
- safety valve
pops off.

Tube fittings are not tight
enough.

Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution. DO NOT
OVERTIGHTEN.

Air leaks at
fittings.

Air leaks at
pressure switch
release valve.
(if equipped)

Defective pressure switch
release valve.

Contact a Trained Service
Technician.

Air leaks in air
tank or at air
tank welds.

Defective air tank.

Air tank must be replaced.

Do not
repair

the leak. Do not drill into,
weld or otherwise modify
air tank or it will weaken.
The tank can rupture or
explode.

Air leaks
between head
and valve plate.

Leaking seal.

Contact a Trained Service
Technician.

Air leaks at or
inside check
valve

Check valve seat damaged.

A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor
is shut off. Replace check
valve. Refer the "To Replace
or Clean Check Valve" in the
"Service and Adjustment"
section.

Advertising