Oilless Reciprocating Air Compressor Pumps

Maintenance Schedule

Operating Hours

Item

Action needed

500

2500

5000

10,000

15,000

20,000

Remarks

Tank

Drain moisture

Daily

Drain tank daily

Inlet Air Filter

Replace

(Every 2,500 hrs or less)

Blower Fan

Clean

Fan Duct

Clean

Compressor Fins

Clean

(Every 2,500 hrs or less)

Bearings

Replace

Compression Rings Replace

Wrist Pin Bearing

Regrease

*Note 4

Piston Set

Replace

Cylinder

Inspect

Unloader Set

Replace

Gasket Set

Replace

Bearing Seal Wrist

Pin

Replace

V-belt

Inspect, replace

*Note 3

Pressure Switch

Confirm operation

Magnetic Starter

Inspect

Replace if contact
points deteriorated

Safety Valve

Confirm operation

(Every 2,500 hrs or less)

Pressure Gauge

Inspect

(Every 2,500 hrs or less)

Inspect

Replace

NOTES:
1. Inspect and perform maintenance periodically according to maintenance schedule.
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse,

shorten the cycle time and do maintenance accordingly.

3. The tension of the V-belt should be adjusted during the initial stage (500H) and inspected every 2,500 hours afterwards.

Proper belt tension for 1 to 3 HP units is 2-3 lbs./.5” deflection; for 5 to 15 HP units, 4-6 lbs./.5” deflection.

4. See page 8.

Air Filter Replacement

1. Remove wing nut or spring clips

2. Remove canister and wipe inside clean with dry cloth.

3. Remove and discard filter cartridge.

4. Install new filter cartridge. Do not attempt to clean and reuse filter cartridge.

5. Wipe inside clean with dry cloth.

Figure 5 - Air Filter Replacement