General safety information, Notice, Caution – Powerex Medical Packing System MPQ User Manual

Page 2: Danger, Warning, Medical package system

Advertising
background image

To help recognize this information,
observe the following symbols.

Danger indicates
an imminently

hazardous situation which, if not
avoided, will result in death or serious
injury.

Warning indicates
a potentially

hazardous situation which, if not
avoided, could result in death or
serious injury.

Caution indicates a
potentially

hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.

Notice indicates

important

information that, if not followed, may
cause damage to equipment.

Unpacking

RECEIVING THE UNIT
Immediately upon receipt of the oilless
compressor, inspect for any damage
which may have occurred during
shipment.
The compressor nameplate should be
checked to verify the correct model
and voltage as ordered.

Do not operate

unit if damaged

during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.

General Safety Information

The following safety precautions must
be observed at all times:

1. Read all manuals

included with this
product carefully. Be
thoroughly familiar with
the controls and the
proper use of the equipment.

2. Follow all local electrical and safety

codes, as well as in the United
States, the National Electrical Codes
(NEC) and Occupational Safety and
Health Act (OSHA).

3. Only persons well acquainted with

these rules of safe operation should
be allowed to use the equipment.

4. Keep visitors away and NEVER allow

children in the work area.

5. Wear safety glasses and

use hearing protection
when operating the
unit.

6. Do not stand on or use

the unit as a handhold.

7. Before each use, inspect compressed

air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or

!

WARNING

NOTICE

!

CAUTION

!

WARNING

!

DANGER

2

Medical Package System

replace defective items before
using.

8. Check all fasteners at frequent

intervals for proper tightness.

Electrical equipment and
controls can cause
electrical arcs that will
ignite a flammable gas or
vapor. Never operate or
repair in or near a flammable gas or
vapor. Never store flammable liquids
or gases in the vicinity of the
compressor.

An ASME code
safety relief valve,

with a setting no higher than the tank
maximum allowable working pressure,
MUST be installed in the air lines or in
the tank. The ASME safety valve must
have sufficient flow and pressure
ratings to protect the pressurized
components from bursting. The flow
rating can be found in the parts
manual.

Do not operate
with pressure

switch or pilot valves set higher than
the tank maximum allowable working
pressure.

9. Never attempt to adjust ASME safety

valve. Keep safety valve free from
paint and other accumulations.

Never attempt to repair or
modify a tank! Welding,
drilling or any other
modification will weaken the tank
resulting in damage from rupture or
explosion. Always replace worn,
cracked or damaged tanks.

Drain liquid from

tank daily.

10. Tanks rust from moisture build-up,

which weakens the tank. Make sure
to drain tank regularly and inspect
periodically for unsafe conditions
such as rust formation and
corrosion.

11. Fast moving air will stir up dust and

debris which may be harmful.
Release air slowly when draining
moisture or depressurizing.

Installation

Disconnect, tag and lock
out power source then
release all pressure from
the system before attempting to
install, service, relocate or perform any
maintenance.

!

WARNING

NOTICE

!

DANGER

!

CAUTION

!

WARNING

!

WARNING

Do not lift or move

unit without

appropriately rated equipment. Be sure
the unit is securely attached to lifting
device used. Do not lift unit by holding
onto tubes or coolers. Do not use unit
to lift other attached equipment.

Installation of
inlet/outlet air

plumbing from the compressor flange
and eletrical connection must be in
accordance with National Fire
Protection Association (NFPA99) Code
Compliance for Medical Gas Breathing
Air (Level 1).

INSTALLATION SITE
1. The oilless compressor must be

located in a clean, well lit and well
ventilated
area.

2. The area should be free of excessive

dust, toxic or flammable gases and
moisture.

3. Never install the compressor where

the surrounding temperature is higher
than 105

o

F or where humidity is high.

4. Clearance must allow for safe,

effective inspection and
maintenance.

5. If necessary, use metal shims or

leveling pads to level the compressor.
Never use wood to shim the
compressor.

VENTILATION
1. If the oilless compressor is located in

a totally enclosed room, an exhaust
fan with access to outside air must be
installed.

2. Never restrict the cooling fan exhaust

air. Maintain a minimum of 3 feet of
clearance around entire unit.

3. Never locate the compressor where hot

exhaust air from other heat generating
units may be pulled into the unit.

WIRING
All electrical hook-ups must be
performed by a qualified electrician.
Installations must be in accordance
with local and national electrical codes.
Use solderless terminals to connect the
electric power source.
PIPING
Refer to the general product manual.
1. Make sure the piping is lined up

without being strained or twisted
when assembling the piping for the
compressor.

2. Appropriate expansion loops or

bends should be installed at the

!

WARNING

!

CAUTION

MANUAL

Minimum Clearances

Above

24”

Other sides

36”