POSIFLEX Business Machines CR-4000 User Manual

Page 4

Advertising
background image

4

3). Set S1 for security code to open cash drawer. In normal practice, the security code is

suggested to be a non-displayable ASCII character. For. example, a hexadecimal
number between 01 to 1F. Please refer to rear panel illustration below.

CR4001/ 4101/ 4211/ 4002/ 4102/ 4212/ 4003/ 4103/ 4213 Rear panel illustration.







S1

Set security code. (Default Setting: BIT 1,2,3 OFF and BIT 4,5,6,7,8 ON. Security
code is 07H)

BIT

1 2 3 4 5 6 7 8

Number to be added to the
security code if OFF.

1 2 4 8 16

32

64

128

S2

BIT1 ON and BIT2 OFF to receive security code via Pin2 of P4 (DB9F).
BIT1 OFF and BIT2 ON* to receive security code via Pin3 of P4 (DB9F).
BIT3 OFF and BIT4 ON for dedicated RS-232C.
BIT3 ON and BIT4 OFF* for non-dedicated RS-232C.
(*denotes factory default setting)

CR4004 / 4104 / 4214

1).

Open the PC case. Put the metal
bracket with power connector into one
of the I/O windows.

2). Connect the cable to the HDD type

power connector of PC power supply.
See illustration below. Then close the
PC case.

3). Connect the DB-9 connector to the

computer's serial port of COM1 (or
COM2). Connect the 4P phone plug connector to the added I/O bracket. See below
illustration.

AC 12V I/P

SERIAL O/P (DB9M)

SERIAL I/P (DB9F)

PARALLEL O/P (DB25F)

PARALLEL I/P (DB25M)

1

8 4

1

GROUND

S2

S1

Switch is ON when pushed up

616P PHONE JACK

POWER CORD