Troubleshooting (basic)/error code/message – Panasonic CF-T7 User Manual

Page 32

Advertising
background image

32

Get

ting St

arted

U

seful In

formati

on

Troubleshooting

Appendix

Troubleshooting (Basic)/Error Code/Message

Follow the instructions below when an error code or message appears. If the problem persists or if the error code/mes-
sage displayed is not shown here, contact your technical support office.

To start the Setup Utility

A

Restart the computer.

B

Press F2 while [Panasonic] boot screen is displayed.

An unnecessary backup
area is present (is left) when
Recover Pro is not installed.

A

Access [http://www.phoenix.com/en/Customer+Services/Utilities/
Recover+Pro+6.htm#Where], and download/install “Cleanup Utility for Recover Pro 6”.

B

Delete the backup area using “Cleanup Utility for Recover Pro 6”.

Some parts of the hard disk
cannot be File Backed up.

The hard disk area encrypted by security software may not be backed up. Exclude the
area from the File Backup object.

Reference Manual

The Reference Manual is not
displayed.

Install Adobe Reader.
A

Log on to Windows as an administrator.

B

Click [start] - [Run], input [c:\util\reader\AdbeRdr70_enu_full.exe], then click [OK].
Follow the on-screen instructions.

C

Update Adobe Reader to its latest version.
If your computer is connected to the internet, start up Adobe Reader and click [Help] -
[Check for updates now].

Others

No response.

Press

Ctrl+Shift+Esc to open Task Manager and close the software application that

is not responding.
An input screen (e.g., password input screen at startup) may be hidden behind another
window. Press

Alt+Tab to check.

Slide the power switch for four seconds or longer to shut down the computer, and then slide
the power switch to turn it on. If the application program does not work normally, uninstall and
reinstall the program. To uninstall, click [start] - [Control Panel] - [Add or Remove Programs].

Error Code/Message

Error Code/Message

Solution

0211 Keyboard error

Disconnect external keyboard.

0251 System CMOS
checksum bad -
Default configuration
used

An error has occurred in the memory of Setup Utility settings. This occurs when the memory con-
tent is changed by an unexpected program operation, etc.

Start the Setup Utility and return the settings to the default values, and then change the set-
tings as necessary.
If the problem persists, the internal clock battery may need to be replaced. Contact your tech-
nical support office.

0271 Check date and
time settings

The date and time settings are not correct.

Start the Setup Utility and set the correct date and time.
If the problem persists, the internal clock battery may need to be replaced. Contact your tech-
nical support office.

0280 Previous boot
incomplete - Default
configuration used

Startup has failed repeatedly, so the Setup Utility settings have been returned to the default val-
ues to startup the computer.

Start the Setup Utility and return the settings to the default values, and then change the set-
tings as necessary.

Press <F2> to Setup

Write down the error details and press

F2 to start the Setup Utility. Change the settings if

necessary.

Operating System not
found

The operating system is not installed in the floppy disk or the hard disk that you are going to boot from.

If using a floppy disk, change the disk to the one you can use for boot.
If using the hard disk, check if the hard disk is recognized in [Information] menu of the Setup
Utility. If the hard disk is recognized, perform the reinstallation (

page 27). If not, contact

your technical support office.
If a device is connected to the USB port, disconnect the device, or set [Legacy USB Support]
to [Disable] in the [Advanced] menu of the Setup Utility.

Recover Pro