Menu structure – Paradyne COMSPHERE 3811PLUS User Manual

Page 9

Advertising
background image

9

3980-A2-GZ41-20

June 1998

To change a factory template using AT commands,

perform the following steps.

"

Procedure

1. Enter the appropriate factory configuration

command (&Fn) followed by the &W0 command
to store the configuration in Active (Saved) and
the Z command to reset the modem.

TYPE: AT&Fn&W0Z

Where: n is one of the following Factory

configurations:

0 is Async Dial
1 is Sync Dial
2 is Sync Leased (Answer Mode)
3 is UNIX Dial
4 is Sync Leased (Originate Mode)
5 is Cellular (Mobile)
6 is Cellular (PSTN)

PRESS: Return (Enter)

2. The selected factory configuration is saved and the

modem is reset.

Synchronous factory preset configurations (&F1, &F2,

and &F4) inhibit AT command control. To regain AT
command control, you must use the SDCP to load a
different factory preset configuration.

The AT commands &F5 and &F6 are available only if

Enhanced Throughput Cellular (ETC) is installed.

Menu Structure

The menu tree accessible from the SDCP contains the

following branches:

Call Setup

Used to dial, disconnect, and
answer telephone calls as well
as store up to 10 telephone
numbers in directory locations.

Status

Used to monitor the current
status of the VF line and DTE
interface as well as view the
identity of the modem.

Test

Used to begin and end various
modem tests.

Configure

Used to change and save the
modem’s configuration
options.

Control

Used to control the modem’s
hardware and software
functions.

Remote

Used to access and control a
remote 3800Plus series
modem.

Security

Used to control the modem’s
dial access security. Appears
only if the optional security
feature is installed.

The following pages show the general menu structure

of the SDCP displays. The model, installed features, and
configuration options all may affect what is actually
displayed at each level of the menus.