Handle actuation vs. spool direction, Open-center directional control valve vo40, Technical information – Parker Hannifin VO40 User Manual

Page 13: Push handle pull handle

Advertising
background image

9

Parker Hannifin Corporation

Open-Center Directional Control Valve
VO40

Catalog HY17-8505/UK

Handle Actuation vs. Spool Direction

Push Handle

Pull Handle

• Spool Out
• Energize port “B”
• Port “A” to tank

• Spool In
• Energize port “A”
• Port “B” to tank

Left-Hand Joystick

Spool OUT - Section 1

Power to “B” Port

Spool IN – Section 1

Power to “A” Port

Spool IN – Section 2

Power to “A” Port

Spool OUT – Section 2

Power to “B” Port

Right-Hand Joystick

Spool OUT - Section 2

Power to “B” Port

Spool IN – Section 2

Power to “A” Port

Spool OUT – Section 1

Power to “B” Port

Spool IN – Section 1

Power to “A” Port

A

B

TANK

OPEN
CENTER

PARALLEL
PATH

TANK

OPEN
CENTER

PARALLEL
PATH

Note:

Circuit reflects spool
position, not handle
position.